2/4
1 : Wall Hz transmitter
2 : 1/5 channels Hz transmitter
3 : Color Multi 16 channels transmitter
4 : Hz timer
Transmitters range:
20 m through 2 concrete walls.
- Do not position the transmitter near metal in order to
avoid range losses.
Location of the “PROG” key on Hz transmitters:
1
2
3
4
1
2
3
4
Compatible transmitters
3
End limits adjustment
4
If the installation includes several motors, only one motor is to be powered during this programming procedure.
It will eliminate interferences with the other motor during the procedure.
>>
ON
>>
>>
3s
a
OK
>>
>>
>> 4.3
>> OK >> 4.3
b
1
2
3
1
2
3
4.1
- Switch the motor ON.
- Simultaneously press the UP and DOWN keys of a Hz transmitter. The
motor will run for 0,5 second in one direction, then in the other.
The
transmitter now controls the motor in unstable mode
, move to
stage 4.2.
4.2- Checking the rotation direction:
Press the UP key of the transmitter:
a-
If the motorized tube runs in the UP direction , move to next stage (4.3).
b-
If the motorized tube runs in the DOWN direction, reverse the rotation direction by pressing the STOP key for at least 3 seconds. The motor will
confirm the reversal of the rotation direction by running for 0,5 second in one direction, then in the other direction. Move to the stage 4.3.
4.3- Adjustement of the end-limits : memorizing the end points:
The end-limit adjustement can be done in two ways:
- First you can memorize the DOWN position
(a)
and then the UP position
(b)
.
- First you can memorize the UP position
(b)
and then the DOWN position
(a)
.
1- Position the motor on the DOWN end limit using the “DOWN” and
“UP” keys.
2- To memorize the DOWN end limit position, press simultaneously the
“STOP” and “UP” keys. The motor will run automatically in the “UP”
direction.
3- Before the motor reaches the UP end limit, press the“STOP” key.
1- Position the motor on the UP end limit using the “UP” and “DOWN”
keys.
2- To memorize the UP end limit position, press simultaneously the
“STOP” and “DOWN” keys. The motor will run automatically in the
“DOWN” direction.
3- Before the motor reaches the DOWN end limit, press the “STOP” key.
a
b