Presentation
1
GB
AUTOSUN SYSTEM
-
2008546 - 2008547 - 2008548
5055194B
Read carefully these instruc-
tions before any use.
1/4
The
Autosun system
is a complete solar powered motor system for
roller shutters in walls and roofs. It comprises:
1-
12V T3.5 DC EHz Motor, 3, 6 or 10 Nm.
2-
12V solar panel
3-
NiMh 12V 2.2Ah battery pack.
As options :
4-
Emergency power supply ref: 9014738. Allows rapid recharging of the battery for
the Autosun system.
1
2
3
4
1 : COLOR+ Wall Hz transmitter
2 : COLOR+ 1/5 channels Hz transmitter
3 : Color Multi 16 / Timer Easy / Timer Multi
transmitters
Transmitters range :
- 1, 2 and 3 :
20 m through 2 concrete walls .
- Do not position the transmitter near metal in order to avoid range losses.
Location of the “PROG” key on Hz
transmitters:
Compatible transmitters
2
Consign concerning the autonomy of the system
3
• The weight of roller shutter must comply with the charts determined for the motors.
Maximum shutter heights are: 1600 mm for 3Nm motors, 2400 mm for 6Nm motors
and 2700 mm for 10Nm motors.
• These consign are based on average annual data and for a roller shutter used for 2
cycles/day (1 cycle = 1 up and 1 down movement). Attention 1 cycle maximum for the
10 Nm motor in case of north orientation (or South orientation for Australia only).
In exceptional years, use the backup power supply to recharge the Autosun’s battery.
• The solar panel should always be placed on the shutter housing so as to be as exposed
as possible to the sun’s rays.
Reminder : Solar panel installation
4
ORIENTATION EAST / WEST / SOUTH
ORIENTATION NORTH
3 Nm
6 Nm
10 Nm
2 cycles/day
1 cycle/day max.
+ Australia (orientation E/W/N)
+ Australia (orientation S)
4.1 - Fastening the solar Panel by riveting
Drilling measurements (mm) for panels placed to the left of the box:
Drilling measurements (mm) for panel placed to the right of the
box:
28
10,5
30
Ø16
449
28
10,5
30
Ø16
449
- Ensure that the cables are not damaged during installation. Smooth the edges of all
the drilled holes.
- Do not put anything on the solar panel that would filter the sun’s ray (e.g.: paint…).
- Keep the photovoltaic cells clean by cleaning them with clean water, using a soft cloth
to avoid scratching them (once a month).
- In winter, do not allow snow to build up on the panels.
- Caution! The cables and connectors must be protected from the roller shutter
movement.
1
2
3
This system was developped to run into the following countries: France, Germany, England, Belgium, Netherlands, Czech Republic, Poland, Ireland, Spain, Portugal,
Italy, Greece, Luxembourg, Denmark, Austria, Switzerland, Hungary, USA (excluding Alaska), Turkey, Lebanon and Australia. For others countries, please contact us.
S.A.S. au capital de 5 000 000 - Z.I. Les Giranaux - BP71 - 70103 Arc-Les-Gray CEDEX - FRANCE - RCS VESOUL B 425 650 090 - SIRET 425 650 090 00011 - n° T.V.A CEE FR 87 425 650 090