background image

 

TLU 600/610

 

Page 11/20

 

NOSP 14540-04 (JULY 2011)

 

 

Press function key F3 (FORW) to view the next remote sensor. 

Each line is numbered. Press the key for that line number (1 to 9) to communicate with 
the corresponding remote sensor. 

Up to this point, the menus have been in French. From this point onwards, the language 
used will be that programmed into the remote sensor (French, English, etc.). 

A  green  LED  in  the  remote  sensor’s  infra-red  head  will,  until  this  point,  have  been 
flashing at a frequency of about 0.5 Hz. From the moment you select this remote sensor, 
the  flashing  rate  will  increase  to  1  Hz  to  indicate  that  communication  has  been 
established  and  will  remain  at  this  frequency  throughout  the  dialogue.  This  makes  it 
easier to identify the selected sensor, and shows that communication is taking place. 

3.4.

3.4.

3.4.

3.4.

 

PICTOGRAMS

PICTOGRAMS

PICTOGRAMS

PICTOGRAMS

    

A number of symbols called pictograms are used to simplify TLU 600/610 operation.  

These pictograms appear in the right-hand column (20

th

 column of the screen). 

3.4.1.

3.4.1.

3.4.1.

3.4.1.

 

C

C

C

C

HARGE INDICATOR

HARGE INDICATOR

HARGE INDICATOR

HARGE INDICATOR

::::

    

""""         """"    

When the battery is charging, the "   " pictogram appears on the right of the screen 
as shown below: 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 

Figure 

Figure 

Figure 6

66

6: 

: battery charging indicator

battery charging indicator

battery charging indicator

battery charging indicator    

3.4.2.

3.4.2.

3.4.2.

3.4.2.

 

L

L

L

L

OW BATTERY LEVEL IND

OW BATTERY LEVEL IND

OW BATTERY LEVEL IND

OW BATTERY LEVEL INDICATOR

ICATOR

ICATOR

ICATOR

::::

    

""""         """"    

When  battery  voltage  falls  to  its  lower  limit,  the  " 

 "  pictogram  appears  on  the 

right of the screen as shown below: 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 

Figure 

Figure 

Figure 7

77

7: 

: low battery level indicator

low battery level indicator

low battery level indicator

low battery level indicator    

The battery must then be recharged using the charger supplied. (see chapter 3.4.5: 
Battery recharging, page 13). 

Do  not  continue  to  use  the  remote  controller  longer  than  half  an  hour  after  this 
symbol  first  appears  without  recharging  the  battery.  To  do  so  could  damage  the 
battery unit. 

Содержание TLU 600

Страница 1: ...glage de test ou de visualisation Cet outil commun tous les t l capteurs SIMRAD Optronics ICARE permet la r alisation d essais de d tection sans utiliser de lampe test et rend ais e la maintenance Op...

Страница 2: ...Manual NOSP 14540 04 JULY 2011 Remote controller TLU 600 610...

Страница 3: ...TTERY UNIT 15 6 PACKAGING AND TRANSPORT 15 7 STORAGE 15 8 Contact details 19 INDEX OF FIGURES Figure 1 TLU Label 3 Figure 2 the remote controller 5 Figure 3 the remote controller key pad 6 Figure 4 co...

Страница 4: ...ors of the series 60 61 62 63 64 and 65 The remote controller is intrinsically safe for use in explosive areas 1 1 1 1 1 1 1 1 I I I IDENTIFICATION AND MA DENTIFICATION AND MA DENTIFICATION AND MA DEN...

Страница 5: ...used to calibrate read current status measure current etc For the flame detector the remote controller can be used to stimulate a flame detection Similarly the language used in these exchanges French...

Страница 6: ...aying 4 lines of 20 characters internal electronics a buzzer a battery unit compartment a keypad with 18 keys including four function keys A charger is supplied with the remote controller Back lit LCD...

Страница 7: ...nnector socket on the left hand side The parts are assembled using cross head self tapping screws and the waterproofness is assured by charged seals graphite Figure Figure Figure Figure 3 3 3 3 the re...

Страница 8: ...pean directive 94 9 CE for products able to work in explosive atmosphere usually called ATEX directive which for the certified devices is shown on the label by the symbol the class of protection and t...

Страница 9: ...led USER Level 2 called MAINTENANCE The remote controller are despatched with the following pass words Level 1 USER one press at the bottom enter Level 2 MAINTENANCE 012345 You can change the pass wor...

Страница 10: ...w of the various menus Autotest Screen ICARE TLU600 r3 0 Code ______ ENTER Autotest OK SCAN ADJT ICARE TLU600 v3 0 Access level CONNEXION 1 SENSOR 1 ZONE 1 2 SENSOR 2 ZONE 1 SELEC 1 9 FORW SCAN In cas...

Страница 11: ...h its number or launch again a Scan When a sensor is selected the remote control goes in REMOTE mode The menus which appear are those of the selected t l capteur C O N N E X I O N 1 G D 0 0 1 S E L 1...

Страница 12: ...y TLU 600 610 operation These pictograms appear in the right hand column 20th column of the screen 3 4 1 3 4 1 3 4 1 3 4 1 C C C CHARGE INDICATOR HARGE INDICATOR HARGE INDICATOR HARGE INDICATOR When t...

Страница 13: ...the green LED on the remote sensor returns to flashing at around 0 5 Hz 3 4 4 3 4 4 3 4 4 3 4 4 T T T TARGETING INDICATOR ARGETING INDICATOR ARGETING INDICATOR ARGETING INDICATOR Once dialogue is esta...

Страница 14: ...wait until the low battery charge indicator appears and then recharge completely over The charger of the TLU600 is an automatic charger with fast load adapted specially CHARGER MAINS 220 Vac Figure F...

Страница 15: ...3 4 6 3 4 6 3 4 6 B B B BACK ACK ACK ACK LIGHTING LIGHTING LIGHTING LIGHTING The remote controller is fitted with a screen back lighting system which provides excellent legibility regardless of ambie...

Страница 16: ...HANGING A BATTERY UNIT IT IT IT To change the battery unit remove the battery compartment by undoing the 6 cross head screws Disconnect the link connector Change the unit Reconnect the link cord maki...

Страница 17: ...20 NOSP 14540 04 JULY 2011 APPENDIX APPENDIX APPENDIX APPENDIX 1 1 1 1 EC conformity declaration for TLU600 EC conformity declaration for TLU600 EC conformity declaration for TLU600 EC conformity dec...

Страница 18: ...TLU 600 610 Page 17 20 NOSP 14540 04 JULY 2011...

Страница 19: ...TLU 600 610 Page 18 20 NOSP 14540 04 JULY 2011...

Страница 20: ...will find an updated list of distributors on our web pages www simtronics eu Email address for general enquiries mail simtronics no Simtronics ASA Kabelgaten 8 kern N ringspark PO Box 314 kern NO 0511...

Страница 21: ......

Отзывы: