Smart Machine Smart Decision
SIM5360-PCIE_Hardware_Design
19
2015-01-22
Note: PCM interface can be control by AT command. For more details please refer to document [1] and
document [2]
Table 10: PCM DC Characteristics
Symbol
Parameter
Min
Type
Max
Unit
V
IH
High-level input voltage
1.26
1.8
2.1
V
V
IL
Low-level input voltage
-0.3
0
0.63
V
V
OH
High-level output voltage
1.35
1.8
1.8
V
V
OL
Low-level output voltage
0
0
0.45
V
4.6.
PERST#
The PERST# pin could be used as an emergency reset. SIM5360-PCIE has power-up reset function, so
power-up reset pulse is not necessary. When the PERST# pin is pulled to ground, the module will be reset. The
PERST# pin is already pulled up in module, so the external pull-up resistor is not necessary.
The following table is the electrical characteristics of The PERST# pin.
Table 11: PERST# Electrical Characteristic
Symbol
Parameter
Min
Type
Max
Unit
V
IH
High-level input voltage
1.7
1.8
3.6
V
V
IL
Low-level input voltage
-
-
0.3
V
T
high-hold
After power up AND-NOT
operation time(keep high
level or keep open)
250
-
-
ms
T
low-hold
Reset low level hold on time
300
-
-
us
The low level pulse time must is longer than 300us
,
The following figure is the timing of reset function.
Figure 5: Reset Timing
Data Ordering
MSB