409977/B
17
Visual inspection
Topics
Visual inspection of the display, page 17
Visual inspection of the Processor Unit, page 19
Visual inspection of the Operating Panel, page 21
Visual inspection of the Transceiver Unit, page 22
Visual inspection of the hull unit, page 24
Environmental inspection of the Transceiver Unit, page 26
Making sure that all SU90 cables are properly connected, page 27
Visual inspection of the display
A visual inspection of the SU90 display is required to verify that the unit has not been
physically damaged during the installation.
Prerequisites
The SU90 has been set up with its hardware units connected as specified in the SU90
Installation manual
. The SU90 is turned off. You need the following equipment:
• Multimeter
Context
This test procedure is only applicable when the display is provided by Kongsberg
Maritime as a part of the SU90 delivery.
Procedure
1
Make sure that the unit’s serial number has been recorded in the list of hardware
items.
2
Make sure that the physical installation of the unit has been completed.