Simrad PI44
70
850-165085 / Rev.B
According to the sensor locations previously described, Spread
1 will now measure the distance from the port trawl door to the
centre clump, while Spread 2 will measure the distance from the
port trawl door to the starboard trawl door.
Readout adjustments
It is necessary to set certain parameters in order to have the PI44
to calculate the distance from the centre clump to the starboard
trawl door.
Headrope sensor:
Footrope sensor:
Trawl opening mode:
Clump sensor:
Door sensor:
Manual trawl marker:
Trawl info
MENU
Exit
GAIN-
GAIN+
(CD11105C)
Trawl data in additional info:
Type of trawl data:
ON
SPREAD
SPREAD 1
SPREAD 2
1
Press the
MENU
button to open the main menu.
2
Press the
WIN
button to select a full screen presentation.
3
Open the
Fishery
menu, and select a
Graphic display
.
4
Press the
ADJ
button to open the
Graphic setup
.
5
Press the
PAGE+
button three -3- times to access the
Trawl info
dialoge.
6
Locate the
Clump sensor
setting, select SPREAD 1.
- As previously defined and described, sensor Spread 1
measures the distance between the port trawl door and
the centre clump.
7
Locate the
Door sensor
setting, select SPREAD 2.
- As previously defined and described, sensor Spread 2
measures the distance between the port and the
starboard trawl doors. This setting allows the PI44 to
calculate the distance between the clump and the
starboard trawl door.
8
Locate
Trawl data in additional info
, select ON.
9
Locate
Type of trawl data
, select SPREAD.
10
Press the
ENT
button to save the settings and exit.
Readouts
Following the configuration and readout adjustments explained,
the following readouts are now available in the
Graphic
display
.
Содержание PI44 C
Страница 2: ......
Страница 265: ...PI Configurator 253 850 165085 Rev B Quit Click this button to close the PI Configurator utility...
Страница 320: ......
Страница 321: ...hjk...