![Simrad PI44 C Скачать руководство пользователя страница 117](http://html.mh-extra.compi44-c_operators-manual_1279152117.png)
Sensors
105
850-165085 / Rev.B
Changing the update rate
It may be required to change the update rate on a sensor, that is
how often it sends information back to the PI44 system. A high
update rate will give frequent information updates, but the
sensor will use more battery power. If you need your batteries to
last as long as possible, you must consider lowering the update
rate.
•
A low update rate will provide you with fewer information
updates, but the battery will last very long.
•
A high update rate will give you frequent information
updates, but the battery will run out faster.
All sensors are provided from Simrad with a default update rate
setting. In some cases you may find that this update rate does
not suit your operational needs. This is a decision you have to
make depending on the local fishing conditions.
How to change the sensor setup
To change the sensor setup, you can call your local Simrad
dealer, or you can do it yourself if you have the proper
equipment, training and the
PI Configurator
software.
The
PI Configurator
application is provided to enable local
sensor configuration. In order to perform this configuration, you
will need a personal computer (desktop or laptop) running
Microsoft® Windows® 2000 or Windows XP®, and a special
cable.
Special configuration of PI Spread
The
PI Spread
sensor is always used with a
PI Remote
sensor,
and these must be configured in a pair in order to make the
transverse communication link work properly. In order to allow
for a dual Spread application, you can use two predefined
configurations:
PI Spread 1
and/or
PI Spread 2
.
The
Remote
sensors are available pre-programmed for these
two pairs, and the sensors are identified as
Remote 1
and
Remote 2
.
The two pairs must be configured as follows:
Configuration Spread sensor
Remote sensor
PI Spread 1
PI Spread (*)
Remote 1
PI Spread 2
PI Spread (*)
Remote 2
(*) = The same
PI Spread
sensor is used for both configur-
ations. By default, it is programmed for
PI Spread 1
. If you
wish to use it for
PI Spread 2
, you must re--configure it using
the
PI Configurator
application.
Содержание PI44 C
Страница 2: ......
Страница 265: ...PI Configurator 253 850 165085 Rev B Quit Click this button to close the PI Configurator utility...
Страница 320: ......
Страница 321: ...hjk...
Страница 322: ...E 2005 Simrad AS ISBN 82 8066 046 1...