Data interfaces
163
850-164692 / Rev.B
Sample data
Subscription type string:
SampleData
Input
Parameters
Range
Default
Unit
SampleDataType
(Power, Angle, Sv, Sp, Ss, TVG20,
TBG40, PowerAngle)
Power
None
Range
(0,20000)
100
m
RangeStart
(0,20000)
0
m
Output
Output for Power, Angle, Sv, Sp, Ss, TVG20, TVG40
struct StructSampleDataHeader
{
DWORDLONG dlTime;
};
struct StructSampleDataArray
{
short nSampleDataElement[30000];
// 16-bits sample in logarithmic format
};
struct StructSampleData
{
StructSampleDataHeader SampleDataHeader;
StructSampleDataArray SampleDataArray;
};
Output for PowerAngle
struct StructSampleDataHeader
{
DWORDLONG dlTime;
};
struct StructSamplePowerAngleArray
{
short nSampleDataElement[60000];
// Composite sample array for power
// and angle
};
struct StructSamplePowerAngleValues
{
int nPowerValues;
// Number of power samples
int nAngleValues;
// Number of angle values
};