background image

*988-10719-001*

Содержание BSM-3

Страница 1: ...ENGLISH BSM 3 Installation Manual simrad yachting com...

Страница 2: ......

Страница 3: ...d other information relating to the product Documentation may be translated to or has been translated from another language Translation In the event of any conflict between any Translation of the Docu...

Страница 4: ...ty to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide re...

Страница 5: ...ays and systems NSE NSO NSO evo2 NSS NSS evo2 http support simrad yachting com Note Make sure the MFD has up to date software refer to the website www simrad yachting com Important text that requires...

Страница 6: ...10 Securing BSM 3 module 11 Wiring 12 Connecting the BSM 3 to your display 13 Transducer connection 13 BSM 3 connectors 14 Transducer with a 7 pin connector 14 Transducer with bare wires 15 Airmar tr...

Страница 7: ...rs ethernet connector Connectors Parts included in package For spare parts and part numbers see Spare parts and accessories on page 22 Item No Description 1 BSM 3 sounder module 1 Ethernet cable 1 8 m...

Страница 8: ...n BSM 3 Installation Manual Item No Description 4 Screws 1 Spare Fuse kit including 3A Fuses and fuse holders 1 Warranty card 1 This manual Required tools and supplies Drill 2 mm 5 64 Drill Bit Screw...

Страница 9: ...y strong with as little vibration as possible If possible mount the unit close to the edges of a panel to minimize vibration Do not run the transducer cabling near the BSM 3 power cables any VHF anten...

Страница 10: ...stallation Manual Securing BSM 3 module Mount the BSM 3 on a vertical surface with the power and transducer cable connections exiting downwards Fasten the BSM 3 by using the 4 stainless steel self tap...

Страница 11: ...he unit For additional safety install grounding cable in ground screw hole as indicated on illustration Recommended 16 awg wire Power The unit has no power key and will turn on when power is applied W...

Страница 12: ...k Expansion Port When connected to an NSO the RJ45 to 5 pin cross over Ethernet cable included with the NSO system must be used Note Above not relevant to NSO evo2 For details refer to the display sys...

Страница 13: ...escription A Power 12 or 24 V DC 9 32 V DC 4 pin connector B Speed Input C Transducer port 1 7 pin blue connector Connect medium or high frequency transducers D Cable gland for independent temperature...

Страница 14: ...ucers will have two connectors and will be labeled Transducer with bare wires Remove connectors 1 Remove cover 2 Remove terminal blocks and disconnect the connector wires for both transducer ports inc...

Страница 15: ...rresponding connector block 11 Tighten the cable gland outer sealing nuts by hand 12 Close the BSM 3 cover and secure the cables Port Gland size Cable diameter Transducer 1 2 M20 10 0 mm 14 0 mm 3 94...

Страница 16: ...req negative G Blue High freq positive H Orange XID I Brown Thermistor XID ground J Shield Low freq depth shield K Black and white or black Low freq negative L Blue white or yellow Low freq positive D...

Страница 17: ...rature settings The transducer s XID wire orange should be connected to the XDCR_ID_HIGH LOW terminal in the TEMP HIGH LOW connector as shown below TEMP HIGH TEMP HIGH GND XDCR ID HIGH J5 1 A B If you...

Страница 18: ...ystem operational Flashing Red Green Software error or unit reprogrammed Restart the unit If still not ok contact Customer Support Network Off No Ethernet connection Check cable Verify that remote uni...

Страница 19: ...HxD mm in 340x100x289 mm 13 38x3 94x11 37 inches Mounting 4 keyholed mounting tabs Power requirements Power consumption Range dependent normally less than 10 W Sonar specifications Power output 250 Wa...

Страница 20: ...0 400 500 600 700 800 900 1000 1500 2000 4000 6000 8000 10 000 12 000 15 000 NOTE all numbers above in ft can be changed to metrics in NSE NSO NSS unit Range control Auto manual range with zoom altern...

Страница 21: ...21 Dimensional drawings BSM 3 Installation Manual Dimensional drawings 340 mm 13 38 320 mm 12 60 100 mm 3 94 109 mm 4 29 250 mm 9 84 289 mm 11 38 6...

Страница 22: ...gland kit 003 8590 00 Fuse Kit Accessories Part no Description 000 0127 51 Ethernet cable yellow 5 Pin 2 m 6 5 ft 000 0127 29 Ethernet cable yellow 5 Pin 4 5 m 15 ft 000 0127 30 Ethernet cable yellow...

Страница 23: ......

Страница 24: ...988 10719 001...

Отзывы: