Troubleshooting | 113
Display
readout
Probable fault
Recommended action
Rudder test
failed
Following conditions may
exist:
Rudder feedback failure
Autopilot Computer current
overload
Bypass/clutch overload
Refer to recommended actions
for the specific probable faults
Rudder moves in only one
direction
Poor connection to one of
the solenoids (continuously
running pump)
Faulty PCB in autopilot
computer
Check the connections
Replace the autopilot computer
Rudder test not completed
within 2 min.
Poor connections to the
drive unit
Faulty PCB in the Autopilot
Computer
Check connections
Check the PCB for traces of
burned transistors. – Replace
the autopilot computer
Rudder moves at full speed
to one side.
Faulty PCB in Autopilot
Computer
Replace the autopilot computer
No active
control unit
Active control unit goes
silent
Press the STBY key on an
"Inactive" unit to reset
Check/repair SimNet cable
Replace the control unit
Rudder Drive
overload
The drive unit shut down
due to an excessive load or
a short circuit
Check the drive unit and drive
unit installation. Look for
mechanical obstructions. Check
the manual steering
Disconnect the drive unit. If
the fault is still present,
replace the autopilot computer
Содержание AP28
Страница 1: ...OPERATOR MANUAL AP28 AUTOPILOT 20222527 A Sw 1 1 English A P 2 8 ...
Страница 6: ...6 AP28 Manual Blank page ...
Страница 45: ...Operation 45 Blank page ...
Страница 50: ...50 Operation Blank page ...
Страница 68: ...68 Main menu Blank page ...
Страница 101: ...Setup at installation 101 DISPLAY 1 DAMPING 1 LANGUAGE NONE FLYBRIDGE COCKPIT DISPLAY 2 ...
Страница 104: ...104 Setup at installation Blank page ...
Страница 108: ...108 IS20 Alarm system Blank page ...
Страница 120: ...120 Optional equipment Blank page ...
Страница 124: ...Glossary 124 Blank page ...