18
3.5 Special Start-Up Modes
There are two start-up modes for the S663 counter. The default start-up mode will be used
every time the counter is powered up by the user. There is one alternate start up mode that will
allow the operator to return the counter software functions to factory default settings.
The alternate start-up modes can only be accessed by pressing and holding certain keys during
the power up sequence.
•
Press and hold both keys on the face of the counter
•
Apply power while holding keys
Key
Keypad behavior
and
Returns parameters to factory defaults. Resets
password to
000
, and all user scaling, operation
modes and set points to factory defaults. Display
will show
freset
.
RESET
ENTER
4 Programming Operations and Parameters
This section details the initial programming options of the S663, presuming all defaults are in
place.
If you are already familiar with the S663 programming, see Appendix B for the Programming
Quick Reference Guide.
To enter the Programming Mode, hold and press .
To return to the Display Mode, press and hold for four seconds when counter is not in an
option menu.
4.1 Password and Security Controls
The security feature helps prevent accidental changes to counter settings.
The password value determines the counter’s security level, as shown in Table 5. If you have
forgotten the password, see section 3.5; Special Start-Up Modes.
1)
After entering the Programming Mode, the first field is Password.
a)
If no password has been assigned, the counter will flash between chpass, for
“Change Password” and the default value, 000.
b)
To change the password, press when the display shows 000. Use the arrow
keys to change the flashing digit to the desired number.
c)
Press to advance to the next digit. Press to accept the password to counter
memory and press it again to advance to the next parameter, Input Setup.
ENTER
RESET
ENTER
ENTER
www.
.com