![Simpson S660 Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/simpson/s660/s660_operation-manual_1278515035.webp)
Menu
Category
Parameter
Name
Choices /
Format
Description
Tech
Note
SP4 000040
*
SP4
Set point #2 High.
Values
:
-99999 to 999999.
Decimal point will appear
according to the current
DP
setting.
4.5
rStPoS 000000
*
Reset Position
Count value is set to this
when an Auto or Manual
Reset event occurs.
Values
: -99999 to
Decimal point
999999.
will appear according to
the user-programmed
DP
position.
4.5
rESEt ArESEt SAbL
di
*
Auto Reset Mode
4.6
SEtuP At
SP1
At SP2
At SP3
At SP4
AFtoP1
AFtoP2
Selects when an auto
reset function is to occur.
Disabled at a set point or
after output times out.
See also the
RSTPOS
parameter in the
Setpnt
Setup
category.
Menu
Category
Parameter
Name
Choices /
Format
Description
Tech
Note
rStbtn EnAbLE
*
SAbL
di
Reset Button
Enable or
disable front panel reset
button.
4.7
PonrSt no
*
YES
Power On Reset
Select
whether count reset
event will occur at
power-up.
4.7
END
Exit Programming
Menu
* = factory default settings
34
www.
.com