15 - ENG
NOTICE:
Risk of property damage. Never pull water supply hose to move pres sure
washer. This could damage hose and/or pump inlet.
• DO NOT use hot water, use cold water only.
• Never turn water supply off while pressure washer engine is running or damage to
pump will result.
• DO NOT stop spraying water for more than two minutes at a time. Pump operates
in bypass mode when spray gun trigger is not pressed. If pump is left in bypass
mode for more than two minutes internal components of the pump can be
damaged.
If you do not understand these precautions, please contact our customer service
department at www.simpsoncleaning.com!
Prior to starting, refer to your Engine Owner's Manual for proper starting
procedure.
1. In a well ventilated outdoor area add fresh, high quality, unleaded gasoline
with a pump octane rating of 86 or higher. Do not overfill. Wipe up spilled
fuel before starting the engine. Refer to
Engine Owner's Manual
for correct
procedure.
NOTICE:
Use of fuels with greater than 10% ethanol are
not approved for use in this product per EPA regulations
and will damage the unit and void the warranty.
2. Check engine oil level. See
Engine Owner's Manual
for correct procedure.
3. Connect the water hose to the water source. Turn the water source on to
remove all air from the hose. When a steady stream of water is present, turn
the water source off.
4. Verify the filter screen (P) is in water inlet of pump.
NOTE:
Convex side faces out.
5. Connect high pressure hose (C) to pump outlet (I).
6. Connect water source (N) to pump inlet (J).
NOTE:
Water source must provide a minimum of 5 gallons per minute at
20 psi.
I
10
C
9
N
J
P
8
WARNING: To reduce the possibility of contamination always protect
against backflow when connected to a potable water system.
7. Choose the correct nozzle for the job to be performed. See
How To Use Spray
Wand
instructions in this section.
NOTE:
If applying a chemical or cleaning
solution, see
How To Apply Chemicals/Cleaning Solvents
instructions in this
section.
8. Turn water source on.
NOTICE:
Risk of property damage. Failure to do so could cause damage to the
pump.