Simpson M245 Series Скачать руководство пользователя страница 3

Stacking Features

The mounting brackets, included with every Mini-Max, can be connect-
ed together.  Multiple units can be mounted in a single opening, allow-
ing perfect alignment.

To punch one hole for multiple units, be sure to adjust the standard
panel cutout dimensions as shown here; otherwise the meters will not
fit properly in the hole.

Mounting multiple units is quick and easy.  Install the first meter (bottom
unit first if stacking vertically).  Position the next mounting bracket snug-
ly against the first one, and slide the second meter into place.  Repeat
for remaining units.

2.68" (68 mm)

 .071" (1.8 mm)

.88" (22.2 mm) 

Standard cutout

Add to standard
when stacking

.

88" (22.2 mm)

2.68" (68mm)

Standard cutout

.16" (4.0mm)

Add to standard when stacking

Horizontal

Vertical

Vertical

Horizontal

Excitation Output

Excitation output is available in the Mini-Max for
powering external transmitters or transducers.
Excitation is available from the EX POS and EX NEG
terminals.  This source is isolated from the measure-
ment input as well as the input power circuits.  The
voltages available are 12VDC or 24VDC, with a
maximum load current of 25 milliamps.  This feature
eliminates the need to mount an external DC power
source for transducers or sensors used in your
application.

Do not exceed an excitation

load current of 25mA!

EX NEG
EX POS

Backlight Option and Decimal Point Selection

Negative image, bright red backlighting is available
in the Mini-Max.  This illumination allows the unit to
be read in low light areas.  Backlighting power is
supplied by the Mini-Max, so no additional external
power is required.

Decimal point selection is accomplished by con-
necting the appropriate DP terminal to the DP
Common terminal.

DP COMMON
    (HOLD)

3 2 1

G

DP 4

DP 2
DP 3

4*

*NOTE:  If the Display 
Hold option is ordered, 
it replaces DP4 on the 
Terminal Connector.

DP 1

DP4

DP3

DP1

DP2