11
Table 1-3. Additional Accessories
o
N
g
o
l
a
t
a
C
n
o
i
t
p
i
r
c
s
e
D
.
Deluxe Case
00812
5
4
5
0
0
p
m
a
l
C
-
p
m
A
2
-
0
5
1
l
e
d
o
M
1.13 Accessory AC High Voltage Probe
The 10,000 volts AC accessory probe is similar to the high voltage DC probes
with the following exceptions: The AC high voltage probe is designed to extend
the 260-8P AC voltage range. The probe can be used with the Simpson 260-8P
10-volt AC range.
NOTE:
Instructions are furnished with each high voltage probe.
1.14 Amp-Clamp Model 150-2
The Simpson Amp-Clamp Model 150-2 allows AC current measurements with-
out breaking the circuit under test. The Amp-Clamp works as a transformer con-
taining a split core for accommodating the conductor which carries the current
being measured. The current-carrying conductor becomes the transformer pri-
mary and a coil in the Amp-Clamp serves as the secondary winding. The Amp-
Clamp output voltage is proportional to the current measured and can be applied
to the 260-8P as an AC voltage.
The Amp-Clamp has a range selector with six positions. Any of the following
current ranges can be used with the 260-8P: 5, 10, 25, 50, 100 or 250 amperes.
NOTE:
Instructions are furnished with each Amp-Clamp.
2.
INSTALLATION
This section contains information and instructions for the installation and ship-
ping of the Simpson 260-8P. Included are unpacking and inspection procedures,
warranty, shipping, power source requirements and operating position.
2.1
Unpacking and Inspection
Examine the shipping carton for signs of damage. If damaged, notify the carrier
and supplier and do not attempt further use of the Instrument. If Instrument ap-
pears to be in good condition, read Operator’s Manual in its entirety. Become
familiar with the Instrument as instructed in the manual, then proceed to check the
electrical performance as soon as possible. Also, check that all items listed in
Table 1-2 are included with the Instrument.
After unpacking the Instrument, a 1.5V battery and a 9V battery may be found in
separate envelopes in the box with the Instrument and the test leads. Two alliga-
tor clips for the test leads are in a polyethylene bag. (See Section 5 for instructions
on how to open the battery compartment and install the batteries.
2.2
Warranty
The Simpson Electric Company warranty policy is printed on the inside front
cover of this manual. Read it carefully before requesting any warranty repairs. For
Содержание 260-8P
Страница 1: ...Simpson 260 Series 8P Volt Ohm Milliammeters INSTRUCTION MANUAL...
Страница 3: ...3 NOTES...
Страница 5: ...5 5 2 Battery Replacement 27 5 3 Fuse Replacement 27 5 4 Test Lead Inspection 28 5 5 Care 28...
Страница 29: ...29 NOTES...
Страница 30: ...30 NOTES...
Страница 31: ...31 NOTES...