Original Instructions // English // v34.0 // April 2022 // Page
24
Crushing if the machine falls over
Operator
LO:
0.5
FE:
4
DPH:
2
NP:
1
Risk
Factor:
4
Minimal risk when the Eurover has been properly installed, as the machine is
either bolted down or affixed to a large, stable mobile base unit.
Other
persons
LO:
0.5
FE:
2.5 DPH:
2
NP:
1
Risk
Factor:
2.5
As above.
Control
measures
The Eurover must be installed by authorised, qualified personnel in
accordance with the procedures set out in
. The mounting anchors must
be fixed into a flat 40MPa concrete surface at least 150mm thick.
When fitted with a mobile base, the Eurover must not be operated on
surfaces with a slope greater than 12%.
Comments
Electrocution or electric shock
Operator
LO:
1
FE:
4
DPH:
15
NP:
1
Risk
Factor:
60
Some risk is always present with mains power leads, especially in wet
environments.
Other
persons
LO:
1
FE:
2.5 DPH:
15
NP:
1
Risk
Factor:
37.5
As above.
Control
measures
Electrical work must only be carried out by a qualified electrician.
All power sockets must be fitted with a Residual Current Device (RCD).
All power leads must be checked and tagged by a registered electrician at
regular intervals. Damaged leads must be promptly repaired or replaced.
Comments
The Eurover is earthed and complies with AS60204.1 wiring standards.
Contamination from tipping toxic powder and liquid
Operator
LO:
2
FE:
4
DPH:
1
NP:
1
Risk
Factor:
8
When tipping power or liquid, some exposure to the product being tipped is
unavoidable.
Other
persons
LO:
2
FE:
4
DPH:
1
NP:
1
Risk
Factor:
8
As above.
Control
measures
Appropriate PPE must be worn when operating the Eurover.
The operator is responsible to ensure that all other persons are well clear of
the working area.
Powder should only be tipped in calm environments without wind.
Comments
Substances of a toxicity that cannot be protected against with PPE should
not be emptied with a Eurover. Alternative methods should be used.