![Simply Automated DKIT-05 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/simply-automated/dkit-05/dkit-05_getting-started_1278382008.webp)
Getting Started DKIT-05
Landscape-Outdoor Lighting Kit
Simply Automated, Incorporated
6108 Avenida Encinas, Suite B, Carlsbad, CA 92011 USA
Technical Support:
www.simply-automated.com
or
800-630-9234
452-0001-0005WEB Rev. B Revised: September 22, 2011
8
The scheduler will show the first event “01)”. With the cursor in the event
•
um er field, press the Dow button
ime to scroll to the next event “02)”.
•
u pass 019, press the Down button to go back, so
“019” is in the device ID field.
•
lower case if you do not want this event to run on that day.
•
de to “R” run, so the event will be active in the
•
plus 15 minutes “DSK+15” (or your desired ON time).
•
scroll the OFF time to dawn (sunrise) “DWN+00” (or your desired OFF time).
•
Down button to set the Event type to “D0”, 100% ON.
button saves the changes made. Pressing Menu button will exit back to the
y toggling between ON and OFF each time Enter
is pressed.
F at dawn, when the scheduler is in the normal runtime (RUN) schedule
2)”:
. With the scheduler plugged into power, the Idle screen should be
01)018 SMTWTFS R
DSK+00 11:00P D0
n
b
n
one t
With the cursor highlighting the event number “02)", press the Right button to
move the cursor over to the Device ID number field. Press the Up button to scroll
up to Device number 019. If yo
Press the Right button to move the cursor over to the days of the week field. Pressing the Up or Down button
on any of the days of the week will change the capital letter to a lower case letter. Capital letter indicates an
ON day; lower case indicates an OFF day for this second “02)” event. Leave all the initials of the days of the
week (Sunday through Saturday) capitalized if you want the event to run every day; or change any day to a
02)---SMTWTFS R
12:00A 12:00A LA
02)019 SMTWTFS R
12:00A 12:00A LA
Press the Right button to move the cursor to the event mode field. Using the Up
or Down buttons set the event mo
normal runtime schedule mode.
Press the Right button to move the cursor to the hours segment (not the
minutes) of the ON time field. Press the Up button to scroll the ON time to dusk
Press the Right button to move the cursor to the hours segment of the OFF time field. Press the Up button to
02)019 SMTWTFS R
DSK+15 DWN+00 LA
02)019 SMTWTFS R
DSK+15 DWN+00 DO
Press the Right button to move the cursor to the Event Type field, then press the
Press the Enter button to save the event. You’re done setting the second event.
•
Helpful Hint: Pressing the Enter
enu without saving changes.
M
Helpful Hint: Pressing the Enter
button when the cursor is on the Event number (e.g. “02”) will test the event
b
Section 4.d. Testing Event 02) for Relay Module #019
The second relay module #019 (as labeled on the back of the unit) was set to turn ON at dusk plus 15 minutes
and OF
mode. To test this second event
“0
Test Event 02)
isplayed:
d
•
From the Idle screen press the Down button and the first event will be displayed,
press the Down button a second time to view the second event “02)”.
•
With the cursor on “02)” press the Enter
button to activate (turn on) the event.
Press the Enter
button again to deactivate (turn off) the event. You should see
the relay module #019 and the connected load (transformer) turn ON and OFF as you press the Enter
button.
02)019 SMTWTFS R
DSK+15 DWN+00 DO
Helpful Hint: If the connected load (transformer) does not turn ON/OFF, check that the relay module controlling
the load is labeled #19 (on the back of the unit) and make sure the event was saved correctly (e.g. matches
icture above with “DO” shown on the bottom right of the display). Check that the relay module is powered
p