Getting Started DKIT-05 

Landscape-Outdoor Lighting Kit

 

Simply Automated, Incorporated 

6108 Avenida Encinas, Suite B, Carlsbad, CA  92011 USA 

Technical Support:  

www.simply-automated.com

 or 

800-630-9234

 

  452-0001-0005WEB Rev. B   Revised: September 22, 2011

 

11 

 

 

Lamp Modules                                     Relay Modules                                  Dimmers                

 
 
 
 
 
 
 
 
  UML7         UML8                                        UMA25                   UMA26 

 

 

  

 

 

 

 

 

 

 

 

 

       US1W9          US1W10

  

 

Tabletop Controllers 

 

       Deluxe Dimmers       

Controlled Receptacles 

(with 4 or 8-button scene control) 

    (with 4-button scene control)   

(top receptacle controlled  

 

 

 

 

 

 

 

 

 

 

 bottom receptacle always on)

 

 

 
 
 
 
 
 
 
 
 

 

US2TP11     USQT22   US28OTP23 

           US2W12         US2W24    

     URD27 

       URD28

 

 

 

Important Note: only one of each pre-configured accessory model number can be ordered per home 
installation. 

 

 

 

Section 6:  In Case of a Problem 

Phone: 760-431-2100 Ext. 138 Monday-Friday 8AM-5PM (Pacific Time) for assistance, or write to 

[email protected]

 

Phase Coupler

: Your home should be no more than 2500 square feet and have only one breaker panel.  A phase 

coupler is required in some home installations; especially homes > 2500 square feet or homes with more than 1 
breaker panel.  If you have tested the scheduler for each relay module, but one or more of the relay modules do 
not turn on, the circuits in your home may need phase coupling or phase alignment.  

 

All homes have a 240V feed to the main breaker panel box, where the 240V is separated into 120V in two 
phases, an A and B.  You will need to install a phase coupler, or use devices on one phase (align or move lighting 
circuits, at the breaker, that have these dimmers and modules to either phase A or B, not both), see 

http://simply-

automated.com/products/cats/phase_couplers.php

 for options. 

 

Model # 

Description 

ZPCI-P30A 

Plug-In Inverting Phase Coupler, fits a standard (NEMA 10-30) 240VAC / 30 Amp clothes 
dryer type outlet 

ZPCI-P50A 

Plug-In Inverting Phase Coupler, fits a standard (NEMA 10-50) 240VAC / 50Amp clothes 
dryer type outlet 

ZPCI-W 

Wire-in Inverting Phase Coupler 

ZPCI-B  

Breaker Panel Inverting Phase Coupler 

Содержание DKIT-05

Страница 1: ...Lighting Relay Starter Kit Model DKIT 05 Simply Automated Pre Configured SimplySmartTM Series Utilizes SimplySmartTM technology to make installation a breeze No computer programming required Simple n...

Страница 2: ...t Includes 2 Appliance relay Modules and 1 Scheduler Timer Controller Getting Started Section 1 Very Important Pre Installation Notes Your home should be no more than 2500 square feet and have only on...

Страница 3: ...trolled by the scheduler or other pre configured scene controllers Go to the location of the second relay module labeled 19 and repeat the steps above to ensure the relay module and the connection to...

Страница 4: ...Right or Left button to the Day of the Week field and use the Up or Down buttons to set the day of the week Find an accurate clock e g cell phone time referenced on a TV station or go to www time gov...

Страница 5: ...ter button and the scheduler will calculate sunrise dawn and sunset dusk for your location Press the Enter button again to save these settings and return to the main Menu You are done setting the Loca...

Страница 6: ...be set to turn ON at dusk and OFF at 11PM when the scheduler is in the regular runtime RUN schedule mode If you would like to set ON OFF times other than Dusk 11PM feel free to do so Set Event 01 Wit...

Страница 7: ...he cursor on 01 press the Enter button to activate turn on the event Press the Enter button again to deactivate turn off the event You should see the relay module 18 and the connected load transformer...

Страница 8: ...ge any day to a 02 SMTWTFS R 12 00A 12 00A LA 02 019 SMTWTFS R 12 00A 12 00A LA Press the Right button to move the cursor to the event mode field Using the Up or Down buttons set the event mo normal r...

Страница 9: ...b Section 4 e Setting Event 03 for a Group SCENE of Modules The relay modules 018 and 019 as labeled on the back of the units are pre configured to operate with the optional 4 and 8 button scene contr...

Страница 10: ...when pressing the Enter bu ection 6 S Section 4 g Other Functions of the Scheduler Timer To learn more about the Scheduler Timer and functions such as deleting an event or setting randomness please r...

Страница 11: ...0 square feet and have only one breaker panel A phase coupler is required in some home installations especially homes 2500 square feet or homes with more than 1 breaker panel If you have tested the sc...

Страница 12: ...p to 250 devices using your PC and UPStart software Devices include single rocker dimmers deluxe dimmers with different faceplates up to 8 buttons lamp or appliance modules tabletop pedestal with 4 or...