SimpliFire • SF-INS25, SF-INS30, SF-INS35 • 2042-970 • 3/21
14
Height
Rear Width
Depth
Front Width
Figure 4.9
Minimum dimensions for installation into an existing fireplace.
MODEL
FRONT WIDTH REAR WIDTH
HEIGHT
DEPTH
SF-INS25
in.
25
18
16-3/8
11-3/8
mm
635
457
416
289
SF-INS30
in.
30
23
20-5/8
11-3/8
mm
762
584
524
289
SF-INS35
in.
35-1/8
28-1/8
23-3/8
11-3/8
mm
892
714
594
289
Position the Appliance
Position the appliance within the opening of the fire
-
place. Level the appliance with included leveling brack-
ets, use shims if necessary.
Once the leveling brackets and surround are securely
attached to the appliance, it can be fit into the existing
fireplace.
1.
Place a protective cover over the finished flooring in
front of the fireplace or wall opening.
2.
Locate the appliance in front of the fireplace opening.
3. Connect the power cord to the receptacle if the
electrical service is located inside the existing fire-
place. The cord will need to be loosely coiled inside
the cavity along the right side of the appliance.
Note:
If the power supply is located outside the fireplace,
the cord can be routed through the bottom cor ner of the
surround to a nearby outlet.
4. If necessary, adjust leveling brackets to achieve
desired height.
5. Slide the appliance into the opening until the decora-
tive front, or optional surround (if installed), contacts
the wall.
6. Note any gaps between the decorative front, or op-
tional surround (if installed), and the wall. Check for
level.
7.
S
lide the appliance from the opening and make ad-
justments to the leveling brackets.
8. Repeat steps 5-7 until the appliance and decorative
front or optional surround (if installed) are flush and
level, and cord is securely routed and terminated
to the receptacle.