1
071807
II. Maintenance Procedures
J.
Step 10.
1. Replace the fan.
2. Note the placement of the washer(s) on the fan. The placement of these washers is critical to allow the fan to tighten
properly on the motor shaft.
3. Tighten the nut
counter-clockwise
.
J.
Step 11.
Reinstall the scroll housing with one screw and three e-clips.
J.
Step 12.
To install the motor:
1. Insure the rubber seal is installed on the dust compartment.
2. Insure the motor seal by the shaft is in good condition.
3. Place the black wire under the motor and connect it. Connect the white wire, (hold the black wire as you place the motor into
the motor compartment to keep from pinching the wire).
4. Place the motor into the motor compartment, (do not push all the way down) shaft side first then fan side, keeping the motor
level as it goes in.
5. Check the back of the vacuum to ensure the scroll housing is not catching on the rubber seal.
6. Rotate the motor as you push it down into the dust compartment. Once in place, the metal motor support should rest in
between the bracket.
7. Raise up the shaft end of the motor, install the wire guide, and push the motor down into place.
Note the proper location of the two cables passing from the clean air motor compartment to the direct air motor
compartment. They should be stored in the channel of the rib wall before the motor cover is reinstalled. If not, the
rib wall could pinch and damage the cables. The cables may also prevent the motor cover from seating properly into
place. Make sure all gaskets are also seated properly.
J. Replacing the Direct Air Motor Fan- Continued
Содержание SYNERGY X9.4
Страница 1: ...Service Manual for X9 5 and Older Models...