background image

8 June 2018 • Simplex Service 800

-637-

8603 • Page 

18 of 19 

Swift-E / Swift-E+ Load Bank Manual 

 

 

 

 

 

 

Number 

Part Number 

Description 

15195030 

Cable Exit, Strain Relief 

24341000

 

Digital Power Meter

 

7BD215514 

Handles, Cable Wrap 

25301000

 

Meter Range Selector Switch

 

15303000 

Rubber Feet 

24251500

 

Over Heat Indicator Lamp

 

25303010 

Master Load and Load Step Toggle 

Switches 

25301000

 

Fan/Control Power Toggle Switch

 

14031000 

Control Fuses 5A, 250V 

10 

14011000

 

Control Fuses 2A, 250V

 

11 

54885650

 

Relay Bale

 

12 

24885000

 

Relay Base Socket

 

13 

24785300

 

Relay

 

14 

50020220

 

Relay Base Bracket

 

15 

25130000 

Resistor 

16 

24892000

 

Din Rail, 

1.75” LG

 

17 

25678501 

Terminal Strip End Barrier 

18 

25678502

 

Terminal Block End Plate

 

19 

25678500 

Terminal Block, 35A, 600V (X17) 

20 

24892000

 

Din Rail, 5.62” LG

 

21 

24827035

 

Relay, General Purpose, 120VAC

 

22 

24882100

 

Relay Base, 3-Pole, Screw Termination

 

23 

12517000 

Plate Mounting 

24 

12103025

 

Circuit Breaker

 

25 

15401000 

1.375” Isolator

 

26 

13027042

 

Contactor, 40A

 

 

 

Table 4: Parts of the Load Bank 

Содержание SWIFT-E

Страница 1: ...8 June 2018 Simplex Service 800 637 8603 Page 1 of 19 Swift E Swift E Load Bank Manual SWIFT E SWIFT E Portable Load Bank...

Страница 2: ...00 637 8603 Page 2 of 19 Swift E Swift E Load Bank Manual This manual was last revised 8 June 2018 For up to date information on this product or others please contact Simplex at 800 637 8603 or on the...

Страница 3: ...ion 10 IV A Load Bank Placement 10 IV B Wiring the load bank 10 IV C Meter Setup Information 10 IV D Current Transformer Ratio 11 IV E Meter Display 11 V Operating Instructions 12 V A Startup 12 V B A...

Страница 4: ...perator must be familiar with its contents and have access to it during operation High Voltage Turn off and disconnect power source before opening this equipment High Temperature Allow hardware to coo...

Страница 5: ...ent If work must be done around an operating unit stand on an insulated dry surface to reduce the risk of electrocution Do not handle any kind of electrical device while standing in water while barefo...

Страница 6: ...extinguisher Its fumes are toxic and the liquid can deteriorate wiring insulation Keep the extinguisher properly charged and be familiar with its use If there are any questions pertaining to fire exti...

Страница 7: ...loy To reduce the risk of electrical shock and short circuiting of elements the element has a non conductive exterior The element is also rust proof vibration proof and shock proof Swift E load banks...

Страница 8: ...43 8 45 8 47 9 50 240V 19 8 20 8 21 9 22 9 24 25 Watts 6250 6500 6750 7000 7250 7500 120V 52 1 54 2 56 3 58 3 60 4 62 5 240V 26 27 1 28 1 29 2 30 2 31 3 Watts 7750 8000 8250 8500 8750 9000 120V 64 6 6...

Страница 9: ...spection is recommended before installation and as part of the 50 hour 6 month maintenance schedule or as a load bank is relocated 1 If the crate shows any signs of damage examine the load bank in the...

Страница 10: ...e Figure 1 Airflow diagram and ensure the area around the load bank is clear of debris The load bank elements are cooled by dual 135mm fans and the unit operator must make allowances for the hot load...

Страница 11: ...ottom display on the meter There are four options Loop which will cycle through three following measurements 1 FrQ which will show the power frequency 2 ACt which will display the load generated measu...

Страница 12: ...ep is activated 2 Activate each load step by switching the desired step on This step if done while the Master switch is activated will apply the load instantly For example while the Master switch is a...

Страница 13: ...Once the cause has been determined and fixed the load bank is ready to be reconnected and the operation can resume VI B Tripped Circuit Breaker The main breaker will trip and the unit will shut off if...

Страница 14: ...nnector Red Accepts 2 0 3 0 and 4 0 cables Up to 600 volts 405 amps Product number 25608721 Male 16 series Cam Lok connector White Accepts 2 0 3 0 and 4 0 cables Up to 600 volts 405 amps Product numbe...

Страница 15: ...E Swift E Load Bank Manual Simplex also offers vinyl and hardshell cases Please contact your sales representative or call the Simplex Inc sales department at 800 637 8603 ext 3 Hardshell shipping case...

Страница 16: ...more information about resetting the circuit breaker Check control fuses on front of load bank to ensure they aren t blown See page 17 to see where the fuses are located Remove faceplate and check lo...

Страница 17: ...8 June 2018 Simplex Service 800 637 8603 Page 17 of 19 Swift E Swift E Load Bank Manual Figure 5 Top of Load Bank 14 20 Figure 6 Front of Load Bank Figure 7 Subpanel 4...

Страница 18: ...le Switch 9 14031000 Control Fuses 5A 250V 10 14011000 Control Fuses 2A 250V 11 54885650 Relay Bale 12 24885000 Relay Base Socket 13 24785300 Relay 14 50020220 Relay Base Bracket 15 25130000 Resistor...

Страница 19: ...properly maintained f parts supplied by buyer for inclusion in finished equipment are not covered by this warranty g components or assemblies specified by buyer with no substitution permissible that...

Страница 20: ...and Fuel Supply needs Simplex Inc Simplex Inc 5300 Rising Moon Road 2100 Boggs Road Springfield IL 62711 Duluth GA30096 800 637 8603 www simplexdirect com This manual and all of its contents Copyrigh...

Отзывы: