background image

Warnings and Cautions — 1

 1  WARNINGS AND CAUTIONS

The following images indicate important safety information:

This General warning symbol points out important 

information that, if not followed, could endanger 

personal safety and/or property.
This Explosion warning symbol points out poten-

tial explosion hazards. 

This Fire warning symbol points out potential fire 

hazards. 

This Electrical warning symbol points out potential 

electrical shock hazards.

• Improper operation of this equipment such as neglecting its

maintenance or being careless can cause possible injury or

death. Permit only responsible and capable persons to install,

operate, and/or maintain this equipment.

• Potentially lethal voltages and amperages are present in these

machines. Ensure all steps are taken to render the machine

safe before attempting to work on the equipment.

• All hardware covered by this manual have dangerous elec-

trical voltages and can cause fatal electrical shock. Avoid

contact with bare wires, terminals, connections, etc., on the

hardware, if applicable. Ensure all appropriate covers, guards,

grounds, and barriers are in place before operating the equip-

ment. If work must be done around an operating unit, stand

on an insulated dry surface to reduce shock hazard.

• Do not handle any kind of electrical device while standing in

water, while barefoot, or while hands or feet are wet. DAN-

GEROUS ELECTRICAL SHOCK MAY RESULT.

• If trained personnel must stand on metal or concrete while

installing, servicing, adjusting, or repairing this equipment,

place insulative mats over a dry wooden platform. Work on

the equipment only while standing on such insulative mats.

• The National Electrical Code (NEC), Article 250 requires the

frame of the equipment to be connected to an approved earth 

ground and/or grounding rods. This grounding will help

prevent dangerous electrical shock that might be caused by a

ground fault condition or by static electricity. Never discon-

nect the ground wire.

• Wire gauge sizes of electrical wiring, cables, and cord sets

must be adequate to handle the maximum electrical current

S

afety

 

information

SymbolS

!

!

C

autionS

Содержание FUELPORT FP-X

Страница 1: ...FUELPORT FULL SIZE FUELPORT...

Страница 2: ...Last Revision Date March 8 2016 For the most up to date information for this product and others please contact Simplex Inc at 800 637 8603 or visit us on the web at http www simplexdirect com...

Страница 3: ...n and Specification 4 4 Unpacking 9 Included Components and Parts 9 Primary Inspection 9 5 Installation 10 Welding FuelPort to Tank 10 Attaching FuelPort to Post 10 Attaching FuelPort to Base 11 Mount...

Страница 4: ...Table of Figures Specifications 5 FuelPort Dimensions 6 Full Size FuelPort Dimensions 7 Recessed Mount FuelPort Dimensions 8 Weld Brackets 10 FuelPort Post 10 FuelPort Base 10...

Страница 5: ...id contact with bare wires terminals connections etc on the hardware if applicable Ensure all appropriate covers guards grounds and barriers are in place before operating the equip ment If work must b...

Страница 6: ...ry rope or board to free the victim from the live conductor If the victim is unconscious apply first aid and seek immediate medical attention Never wear jewelry when working on this equipment Jewel ry...

Страница 7: ......

Страница 8: ...truck The FuelPort is available in two models The standard Fu elPort which is 32 inches tall and has a 7 gallon containment capacity and the Full Size FuelPort which is 51 5 inches tall and has a 20 g...

Страница 9: ...ds 100 F 140 F flash point Diesel fuel Inlet Fitting Size 2 3 or 4 3 internals and 3 NPT outlet Spill Containment FuelPort 7 gallons Full Size FuelPort 20 gallons Surface Finish UL listed powder coat...

Страница 10: ...6 Description and Specification Figure 1 FuelPort Dimensions...

Страница 11: ...Description and Specification 7 Figure 2 Full Size FuelPort Dimensions...

Страница 12: ...8 Description and Specification Figure 3 Recessed Mount FuelPort Dimensions...

Страница 13: ...m ing this procedure The following inspec tion is recommended before installation and as part of a 6 month maintenance schedule or as the fuel port is relocated 1 If the crate shows any signs of dam a...

Страница 14: ...y safety procedures when welding the brackets to your tank Simplex is not responsible for damages or injuries sus tained due to improper safety precautions With the post mount ing option the FuelPort...

Страница 15: ...hardware are sufficient to support the FuelPort s weight Simplex is not responsible for damages occurring as a result of insuffi cient support The Full Size FuelPort can be secured against a wall a f...

Страница 16: ...door 3 Connect delivery hose to hose coupling 4 Open valve on truck and valve in FuelPort 5 Start fill pump 6 Stop fill pump when tank is full or as needed 7 Close truck valve and valve in FuelPort 8...

Страница 17: ...inished equipment are not covered by this warranty g components or assemblies specified by buyer with no substitution permissible that are not normally used by SIMPLEX SIMPLEX reserves the right to re...

Страница 18: ...ide solutions meeting exact requirements from the simplest testing and proving equipment for backup generators to custom designed and engineered mission critical fuel systems At Simplex we are experts...

Страница 19: ...ho Montana Nevada Utah and Wyoming GEORGIA Serving Alabama Florida Georgia North Carolina and South Carolina ILLINOIS Serving Illinois Indiana Kentucky Michigan Missouri and Tennessee MASSACHUSETTS Se...

Страница 20: ...Simplex Inc 5300 Rising Moon Road Springfield IL 62711 6228 2100 Boggs Road Duluth GA 30096 4691 www simplexdirect com 800 637 8603...

Отзывы: