Input Power
Voltage 24 VDC from fire alarm panel; operation range 9 to 30 VDC
Current 123 mA maximum from 24 VDC fire alarm panel supply
Connections Wires to pluggable terminal block, harness included
Data Input
Note:
Connect to
Port B of RS-232
Module
Data Type RS-232 Computer Port Protocol from fire alarm control panel
Connections
Pluggable terminal block (same terminal block as used for input power) connects to
RS-232 module in fire alarm control panel, harness included
Panel 4100ES
4010ES
4100U
4100/4100+/4120
RS-232
Module
4100-6038 4010-9918 4100-6038 4100-0113
Data Output
Data Type Ethernet compatible communications formatted as BACnet IP (internet protocol)
Connections
Ethernet RJ-45 jack located on LAN suppressor module (part of module assembly);
LAN Ethernet output connector to be supplied separately
BACnet Default Settings
Device Instance = 32400; IP Address = 192.168.1.24; Subnet Mask = 255.255.255.0
Status LED Indications
Power, TX, RX, RTX, CTS, DTR, DSR, DCE, and RI; located on the processor assembly
4100-6069 Module Size
2” Slot type module, components are mounted on a metal bracket;
bracket dimensions: 2” W x 10-7/16” H x 4” deep (51 mm x 265 mm x 102 mm)
4010-9915 Module Size
Single block module (4 x 5); uses the modules shown in the diagram below, but packaged
differently
Module Description
RS-232 communications and power are connected to the on-board pc board assembly for
processing; a pluggable harness (supplied) connects to a grounded LAN suppressor
mounted on the chassis; standard Ethernet LAN cable is supplied separately
Operating Temperature Range
32
F to 120
F (0
C to 49
C)
Humidity Range
Up to 93% RH, non-condensing @ 90° F (32° C) maximum
TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. ASHRAE and BACnet are trademarks
of ASHRAE, American Society of Heating, Refrigeration, and Air Conditioning Engineers.
Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA
S4100-0051-3 9/2012
www.simplexgrinnell.com
© 2012 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.
Processor assembly
Interconnection cable
LAN Ethernet cable
connection location, RJ-45
(cable supplied separately)
Power and data connection terminal strip
2” Slot mounting bracket (shown
rotated from mounting orientation)
LAN Suppressor Assembly
Suppressor
grounding
connection
Specifications
BACpac Ethernet Module Details
(4100-6069 shown for reference)