SIMPAL-T2 GSM Temperature Alerter USER MANUAL
9
Saturday to Sunday
•
StartTime
and
EndTime
: Be
consists of 4 digits (hh:mm) and works
on a 24 hour clock. The
StartTime
and
EndTime
should be in the
same day, and the
EndTime
must be later than
StartTime
. Default
settings: 0700 to 2100.
•
MinTemp
and
MaxTemp
: The values are whole numbers, can be set
within the range of -10 to 50 centigrade degree. The difference of
MinTemp
and
MaxTemp
values should not be 0.
•
MinTemp1
and
MaxTemp1
are temperature limits within the
duration. Default
MinTemp1
is 18 and
MaxTemp1
is 24 centigrade
degree.
•
MinTemp2
and
MaxTemp2
are temperature limits beyond the
duration. Default
MinTemp2
is 16 and
MaxTemp2
is 24 centigrade
degree.
•
For example: #07#0#0000#2130#18#24#16#24# , 0000 means time
00:00(hh:mm)AM, 2130 means time 9:30PM.
•
Successful SMS reply
Schedule temperature alert: ON/ OFF
Everyday
Setting time: ****-****
Temp alert range: **-** degree
Other times temp alert range: **-** degree
The alerter will send SMS message when it alarms:
BUILT-IN TEMPERATURE ALERT.
Current temperature reading: **
2.7.3 Disable timing alarm of built-in sensor
Method
The
Master
user sends following SMS message in order to:
Disable timing alarm of built-in sensor (Default):
#06#0#
(23)