5.5 version for steel and fire retardant doors
Design is similar to standard version but for doors with sturdy metal
sections, such as fire doors, or doors with highly protective shielding. This
version is recommended in areas with high interference fields, such as
server rooms, and for all metal doors. The FH version cannot be retrofitted.
If wired networks are used, we recommend using this cylinder version due
to its reduced projection.
Before a locking cylinder is installed into a fire/smoke retardant door, the
fire certification has to be checked first to ensure that conformity is in
place.
It must be ensured that any locking devices or sealing strips do not impede
the orderly operation of the MC.
5.6 TS version
Design as for standard version, but with the additional option of allowing
the cylinder to engage without an identification medium. This cylinder
version can be engaged mechanically with the aid of two buttons on the
inside thumb-turn. This means that no transponder is needed when the
user is on the internal. The cylinder will then engage for five seconds
(configurable) and the door can be opened or locked. Once this time
interval expires, the cylinder rotates freely again on both sides.
The .TS version cannot be retrofit.
5.7 MR option
Design is similar to standard version but the locking cam features fixed
points where it positions itself when disengaged. This version is particularly
suitable for very smooth-running locks with multi-point locking systems.
Please observe the lock manufacturer's declaration of conformity when
combining multi-point locks with a panic function.
5.8 MS version
The Locking Cylinder 3061 can be supplied with stainless steel or brass
colour finish (highly glossy thumb-turn covers).
5.9 SKG or VdS versions (SZ)
The Locking Cylinder 3061 is optionally also available as a VdS cylinder.
The additional mechanical security features ensure that VdS Classes AZ
and BZ or Class SKG*** are achieved. These versions cannot be combined
with the brass and WP versions. The VdS cylinder can only be supplied in
combination with access control (ZK) functions.
Digital Locking Cylinder 3061
(Manual)
5. Versions
19 / 54