Definition: network segments are characterized on the one hand by a particular 
transmission medium (i.e. RS485 cable, RS232 cable, or 915 MHz radio) and on the 
other hand by a separate segment address (GID = GroupID). 

The following SimonsVoss WaveNet network components are available: 

 

7.1 Computers 

Using special communication node software (CommNode), computers can be 
integrated into WaveNet:  

-

  between the user interface and RS232 port, and  

-

  between the user interface and TCP/IP (Internet, Intranet), and  

-

  between TCP/IP and the RS232 port.  

 

 

*

= Lock Node communicates with the allocated lock via 25 kHz (see Administration Building) 

 

7.2 

Router Nodes (general) 

WaveNet Router Nodes are basically used to connect two different network segments 
together; these two may use the same transmission medium (i.e. RS485 to RS485), 
or different transmission media (i.e. RS485 cable to 915 MHz radio). 

Furthermore, data streams arriving from the segments are filtered by the WaveNet 
Router Node so that the only data passed on to the segment downstream from the 
WaveNet Router Node is the data which is supposed to be processed by that 
segment. The WaveNet Router Node blocks out all other data from the downstream 
segment.  

Administration 

Building 

Server with 

LSM 

Client PC with 

SV client 

licence 

Client PC with 

SV client 

licence 

Client PC with 

SV client 

licence 

Building 1 

Building 2 

Building 3 

Application

Administration of different buildings/halls 

(at one location) via existing Ethernet (Intranet) 

 

IP protocol 
on existing 

Ethernet

 

(Intranet) 

 

Содержание WaveNet Radio Network 3065

Страница 1: ...WaveNet Radio Network 3065 Published January 2007...

Страница 2: ...e transmission 7 7 0 WaveNet System 3065 Network components 7 7 1 Computers 8 7 2 Router Nodes general 8 7 3 Router Nodes special versions 9 7 4 Lock Nodes 11 8 0 Network structure 13 9 0 Security 15...

Страница 3: ...12 7 WaveNet Router Node with RS 485 915 MHz Converter 19 12 8 WaveNet Router Node with 915 MHz RS 485 Converter 20 12 9 WaveNet Lock Node 20 Copyright 2007 SimonsVoss Technologies Inc All rights rese...

Страница 4: ...vide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance w...

Страница 5: ...ch as door open door closed door locked battery warning access list break in alarm can be tracked and acted on This enables you to respond to events directly from the central control room WaveNet is a...

Страница 6: ...scientific and medical ISM applications ISM equipment operating in these bands includes wireless phones line of site radio devices and various office communications products The WaveNet network operat...

Страница 7: ...route Intentional interference such as manipulation or sabotage of the transmission route Intelligent methods of avoiding interference and finding alternative routes The speed of data transmission an...

Страница 8: ...ral WaveNet Router Nodes are basically used to connect two different network segments together these two may use the same transmission medium i e RS485 to RS485 or different transmission media i e RS4...

Страница 9: ...us enabling the range to be extended This means that if the radio transmission distance to the Lock Node achieved by the Router Node is too small or if a cable within the network is going to exceed th...

Страница 10: ...bone is wired using a bus comprising a shielded standard CAT5 cable The bus line consists of two data lines Data Data and an earth line This bus line is connected to every RS485 module associated with...

Страница 11: ...veNet Lock Nodes are battery powered and can therefore be integrated into the SimonsVoss WaveNet with no wiring whatsoever This makes the system ideal for installation in an existing building For inst...

Страница 12: ...mon line and one of the colored blue green yellow lines see following diagram In the LDB and LSM user interfaces an open contact has the value 0 while a closed contact has the value 1 In the diagram a...

Страница 13: ...plication known as the SimonsVoss LSM locking system management software However in the example above there is only one single CommNode and thus only one single Central Node with a local subnetwork In...

Страница 14: ...ts A WaveNet Central Node can serve up to 253 segments while each segment can have up to 253 WaveNet Lock Nodes WaveNet Router Nodes Note If you are using the LSM software the network can be divided u...

Страница 15: ...may be variable during particular periods for example critical doors may need to be monitored more frequently at night 9 3 Alarms Alarms are messages which require an immediate response i e break in o...

Страница 16: ...sible although there should be at least 1 5 inches 3 cm between the Lock Node and a metal door frame The maximum distance between the WaveNet Lock Node and the RF Lock is approximately 14 inches 35 cm...

Страница 17: ...ltage supply for all Routers 6 V 12 V DC Power for all Routers Min 3 VA 250 mA at permanent load current peak if both ends are terminated on the backbone 12 4 WaveNet Central Node with 915 MHz radio m...

Страница 18: ...at 19 2 kBaud Frequency 915 MHz Current consumption in receive mode 12 mA at 3 3 V 12 5 WaveNet Router Node as RS 485 Repeater Order number WN RN RS485 RS485 Description WaveNet Router Node as RS485 R...

Страница 19: ...x 40 mm or 3 9 x 2 6 x 5 1 inches 100 x 65 x 130 mm with antenna 12 7 WaveNet Router Node with RS 485 915 MHz Converter Order number WN RN RS485 RF915 Description WaveNet Router Node as a converter b...

Страница 20: ...pply and an external send and receive antenna Dimensions L W H 3 9 x 2 6 x 1 6 inches 100 x 65 x 40 mm or 3 9 x 2 6 x 5 1 inches 100 x 65 x 130 mm with antenna 12 9 WaveNet Lock Node Order number WN L...

Страница 21: ...erference density Maximum transmission power approx 1 mW Sensitivity 95 dBm Frequency 915 MHz Input 3x Floating current pulse approx 35 A for 1ms every 0 5 sec Output Open Drain Maximum switching volt...

Страница 22: ...ents Dimensions H x 1 46 inches x 2 1 inches 37 mm x 53 mm Voltage supply 2 Batteries CR2 3AA Lithium 3 6 V Current consumption Radio transmission 25 mA Radio reception 15 mA Power consumption with no...

Отзывы: