User manual - LIQUID SENSOR DRS-30x
2.
GENERAL CHARACTERISTICS
is designed for conducted liquid presence detection.
Parameters of the detector have been fixed to allow detection of actual presence of liquid on
its electrodes and to be resistant for low impedance conducted surfaces (e. g. wet fingers).
Additional reference electrode prevents detector against false signalising when liquid covers
its surface only. PUSH-PULL output gives an opportunity for connection either to devices
equipped with direct or inverse logic inputs. Wide range of supply voltage (12 - 30V DC) and
operation temperatures (-40°C ÷ +85°C) allow to use the sensor in most systems (e. g. pump
dry run detection, full tank detection etc.)
Approximate resistivity of water
Kind of water
from water
supply system
potable water
mineral water
distilled water
resistivity
0.5 ÷ 5kΩ/cm
1 ÷ 8kΩ/cm
2 ÷ 5kΩ/cm
50 ÷ 200kΩ/cm
3.
TECHNICAL DATA
Power supply voltage
12V...
24
...30V DC
Current consumption
about 5mA (+ output load )
Output
PUSH-PULL
Output max. load
50mA (sink and source)
Output delay
< 100ms
Detection threshold
12kΩ ± 20%
Protection level
IP 67
Material of electrodes
Stainless still, acid resistant
Filling material
polyurethane
Mounting method
thread
Connection
cable 4 x 0.5, polyurethane
Cable length
1...3 m (depending on device version)
Housing type
Housing dimensions
gland M20x1,5 LAPKABEL
28 x 33 mm, thread M20x1,5x9
Weight
50 g
Operating temperature
Storage temperature
-40°C do +85°C
-40°C do +85°C
4
Содержание DRS-30 Series
Страница 11: ...User manual LIQUID SENSOR DRS 30x 11 ...