background image

Table of Contents

3

Page

General Safety .....................................................................................................2

Warranty ..............................................................................................................3

Installation ........................................................................................................4-8

Operation .......................................................................................................9-10

Troubleshooting .................................................................................................10

Repair Parts ........................................................................................................11

For parts or assistance, call Simer Customer Service at 

1-800-468-7867 / 1-800-546-7867

SIMER warrants to the original consumer purchaser (“Purchaser”) of its products
that they are free from defects in material or workmanship.
If within twelve (12) months from the date of the original consumer purchase
any such product shall prove to be defective, it shall be repaired or replaced at
SIMER’s option, subject to the terms and conditions set forth below. Your origi-
nal receipt of purchase is required to determine warranty eligibility.

Exceptions to the Twelve (12) Month Warranty

Five (5) Year Warranty:

If within five (5) years from original consumer purchase any Pre-Charge water
system tank shall prove to be defective, it shall be repaired or replaced at
SIMER’s option, subject to the terms and conditions set forth below.

General Terms and Conditions

Purchaser must pay all labor and shipping charges necessary to replace product
covered by this warranty. This warranty shall not apply to acts of God, nor shall
it apply to products which, in the sole judgement of SIMER, have been subject
to negligence, abuse, accident, misapplication, tampering, alteration; nor due
to improper installation, operation, maintenance or storage; nor to other than
normal application, use or service, including but not limited to, operational fail-
ures caused by corrosion, rust or other foreign materials in the system, or oper-
ation at pressures in excess of recommended maximums.

Requests for service under this warranty shall be made by returning the defec-
tive product to the Retail outlet or to SIMER as soon as possible after the dis-
covery of any alleged defect. SIMER will subsequently take corrective action as
promptly as reasonably possible. No requests for service under this warranty
will be accepted if received more than 30 days after the term of the warranty.
This warranty sets forth SIMER’s sole obligation and purchaser’s exclusive rem-
edy for defective products.
SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR
CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL
OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT
NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE
DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or conse-
quential damages or limitations on how long an implied warranty lasts, so the
above limitations or exclusions may not apply to you. This warranty gives you
specific legal rights and you may also have other rights which vary from state
to state.

Simer Limited Warranty

SIMER • 293 Wright St. • Delavan, WI U.S.A. 53115

Phone: 1-800-468-7867 / 1-800-546-7867 • Fax: 1-800-390-5351

Содержание A5500

Страница 1: ...31 2003 PRINTED IN U S A 1000001410 Rev 5 20 03 OWNER S MANUAL Battery Backup System NOTICE D UTILISATION Système de secours à batterie MANUAL DEL USUARIO Systema de respaldo de la batería AL AR M RE SE T SO FT RE SE T AU DI BL E AL AR M DI SA BL E CH AR GIN G YE LL OW CH AR GE D GR EE N LO W BA TT ER Y AL AR M AU DI BL E AL AR M SIL EN CE PU MP RU N AL AR M A C PO WER ON MIC RO PR OC ES SO R CO N...

Страница 2: ...mended for use on any electrical appliance submerged in water 3 Use this system only for backup sump pump duty in a residential application It is not designed as a pri mary sump pump 4 Do not lift pump by electrical cord Risk of electrical shock Do not lift the pump by the electrical cord lift pump only by the dis charge pipe lifting ring or handle on the pump Lifting by the cord can damage the co...

Страница 3: ... normal application use or service including but not limited to operational fail ures caused by corrosion rust or other foreign materials in the system or oper ation at pressures in excess of recommended maximums Requests for service under this warranty shall be made by returning the defec tive product to the Retail outlet or to SIMER as soon as possible after the dis covery of any alleged defect ...

Страница 4: ...ailure to follow this warning can result in personal injury or death 3 Unplug the pump 4 To separate the primary pump from the discharge pipe A For applications with rubber couplings remove the coupling clamp with a nut driver B For applications without rubber couplings cut the PVC discharge pipe with a hacksaw above the basement floor and at a comfortable level New rubber couplings are included f...

Страница 5: ...here must be a check valve installed in the Primary Sump Pump discharge pipe between the tee and the Primary Sump Pump This will prevent recirculation into the Primary Pump when the Backup Sump Pump comes on 11 Slip a reducer bushing onto the end of the pipe com ing from the primary pump discharge Do not glue this connection yet NOTICE If your discharge pipe diameter is 1 1 4 you will need to glue...

Страница 6: ...and pump assembly 4 Thread the close nipple into the tee Key No 2 FloatSwitch TetherLength 2 5 63 5mm Tee Hose Coupling and Clamps Discharge Pipe Cable Ties 2 Minimum To the back up pump discharge pipe Short length of discharge Pipe length may vary Check valve 3546 1099 S521 Primary Sump Pump Discharge Pipe Figure 4 Back up pump float switch tether length and discharge pipe Figure 5 Method B Make ...

Страница 7: ...terfere with each other Make sure there is plenty of room for the float switch es to swing from their off to their on positions Mark and Glue Assembly 1 Mark the pipe and the fittings at all the connections with a pencil These marks will be used as a reassembly guide while gluing to be sure that every thing is still in the right place and nothing has moved 2 Loosen the rubber coupling and clamp co...

Страница 8: ...battery Positive battery terminal leads are provided Negative lead from the battery Negative battery terminal leads are provided Positive Backup sump Pump Positive pump lead terminal lead BROWN wire Negative Backup sump Pump Negative pump lead terminal lead BLACK wire Positive Float switch Lead Positive float switch terminal WHITE wire Negative Float Switch Lead Negative float switch terminal BLAC...

Страница 9: ...wo or more bad cells the battery is in a heavily discharge state 2 Yellow bicolor charging LED continuously on indicates Constant current charge stage Charger is charging battery at full rated output 3 Yellow bicolor charging LED flashing quickly indicates Constant voltage charge stage Battery cells are being equalized 4 Green bicolor charging LED indicates Float charge stage Battery terminal volt...

Страница 10: ...tact with skin eyes or clothing NOTICE To protect battery case from chipping and gouging do not let battery sit on concrete floor Install battery on a shelf or protective pad plywood 2x4s etc Always install battery in a dry location that is protected from flooding Follow the battery manufacturer s recommendations for maintenance and safe use of battery TROUBLESHOOTING Pump won t run 1 Check all wi...

Страница 11: ...U CTI ON MA NU AL BEF OR E USI NG Included in Fittings Package Includes 1 1 2 x 1 1 4 Reducer Bushings 2 Included with Key No 11 Not illustrated Purchase locally Key No Part Description A5500 1 Rubber Hose Coupling and Clamps U74 68 2 PVC Tee 1 1 2 x 1 1 2 Slip x 1 1 4 FNPTW 1 1 4 U78 846P 3 PVC Pipe Nipple 1 1 4 NPT x Close U37 66P 4 Coupling Check Valve Assembly 1 1 4 FNPT x 1 1 4 FNPT U212 261P...

Отзывы: