![Sime SOLIDA 5 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/sime/solida-5/solida-5_manual_1275116029.webp)
29
FUEL FEEDER FILLING FUNCTION
The “Fuel feeder filling” option (“Charge Pellet” shown on the display) is displayed in the menu only if the heater is OFF, and it is aimed to let the
auger feeder being filled with pellet.
When the key
Set
(key #3) is pressed, the panel changes screen (See “Fig. 53 Pellet feeder filling function”). By pressing
esc
(key #1) the display
reverts back to the previous screen, while the key
Ok
(key #3) starts the function, showing the confirmation (See “Fig. 54 Pellet feeder starting up”).
By pressing the button
esc
(key #1) the previous screen is restored and the function is stopped. When the function is active, it may be stopped by
pressing the button
On/Off
(key #5), while the display reverts back to the START screen.
e s c
O
c
:
h a r g e
G
e l l e t
Pellet feeder filling function
Fig. 53
e s c
8
b i l i t a t i o n
:
h a r g e
G
e l l e t
Pellet feeder starting up
Fig. 54
BURNER POT CLEANING
The “Burner pot cleaning” option (“Cleaning” shown on the display) is displayed in the menu only if the heater is OFF (See “Table 12 Maintenance
menu functions list”), and it is aimed to let the fuel feeder being filled with pellet.
When the key Set (key #3) is pressed, the panel shows a screen similar to that used for filling the auger feeder with pellet (See “Fig. 53 Pellet feeder
filling function”). By pressing esc (key #1) the display reverts back to the previous screen, while the key
Ok
(key #3) starts the function, showing the
confirmation. Stopping the burner cleaning function is done in the same way as for the “pellet filling” function (by pressing again the key #3).
PUMP ACTIVATION
The option”pump activation” option (“Start pump” shown) is displayed in the menu only if the heater is in OFF status and the “HYDRO” mode is
on (See “Table 12 Maintenance menu functions list”). This function is used to turn on the pump to help purge any air in the heating pipe work. This
function works in the same way as the previous two ones.
TECHNICAL MENU
3.3.3.5
This menu is intended for service purposes, and includes the setting of all the items reserved for technical personnel only; accessing this menu is
password protected (See Fig. 55).
e s c
N
O
c
Þ
G
a s s w o r d
>
PASSWORD screen
Fig. 55
The password is split into a letter and a numeric part, which may be changed. The two bottom keys with arrows allows the user to toggle the currently
blinking item; the letter part of the password will be confirmed firstly by pressing the key
Ok
(key #3); after that the numeric part may be confirmed.
If both parts are not set correctly the sequence starts again from the beginning.