47
7.3.2
Fault warnings
If a fault occurs, the screen
“Anomaly in progress”
will appear
in place of the
“Main screen”
. For the main fault codes, a brief
description and suggestions for the user are displayed, based
on the seriousness and the frequency with which the fault re-
appears.
FAULT IN PROGRESS
Contact the Technical Assistance Centre
Name:
xxxxxxxx
Ph.:
yyyyyyyyy
5 - Technical problem
Esc
FAULT IN PROGRESS
Reset boiler
Reset
No flame detection
Fig. 75
The fault may be
transient
(volatile) or it may cause an appliance
block
.
To restore normal operating conditions:
– if the fault is transient, eliminate the cause of the fault
– if the fault causes a block, eliminate the cause of the fault
and then press the
“RESET”
(Reset) button; press the
encoder to confirm.
If there is
“no water in the system”
(no water in the system) or
“low water pressure in the system”
(low water pressure in the
system), there will be a request to fill the system and then to
confirm.
FAULT IN PROGRESS
Fill the system as per boiler's manual
instruction
2 - Low pressure
Fill
FAULT IN PROGRESS
Confirm operation
Confirm
Fig. 76
A list of possible faults is given under "
Fault / malfunction
codes
".
7.3.3
Time Programming
The
control panel
allows up to a maximum of four daily time
bands to be managed for the domestic hot water function and
the heating function described below.
During the programmed time band, the boiler works in COM-
FORT heating mode, while outside the programmed time band
it works in REDUCED heating mode:
– press the encoder
click
to confirm
“Program. Time”
(Pro-
gram. Time) and go into the modifiable area
Confirm
Heating Time Program
0246
81
01 21 41 61 82 02 22 4
[1] 06:00 - 08:00
[2] 11:00 - 13:00
[3] -
[4] 18:00 - 23:00
MONDAY
Day/s
Fig. 77
– turn the
encoder to select the
“Single days”
or the
“Group of days”
– press the
click
encoder to confirm the required selection
and access the first
“Adjustable time” [1]
Heating Time Program
0246
81
01 21 41 61 82 02 22 4
[1] 06:00 - 08:00
[2] 11:00 - 13:00
[3] -
[4] 18:00 - 23:00
MONDAY
Day/s
Confirm
Fig. 78
– turn the
encoder to modify the
“Data/value”
on the ba-
sis of the required time
– press the
click
encoder to confirm the modification and
move to the next
“Data/value”
Heating Time Program
0246
81
01 21 41 61 82 02 22 4
[1] 06:00 - 08:00
[2] 11:00 - 13:00
[3] -
[4] 18:00 - 23:00
MONDAY
Day/s
Confirm
Fig. 79
– continue in this way until all the necessary modifications have
been made for each day of the week or group of days.
NOTE
: The user must work in a CIRCULAR manner, meaning AL-
WAYS MOVING FORWARDS, even if a mistake is made.
m
CAUTION
If NO time band is required, set the start and stop
times of that band to the same value (e.g. [3] 14:00-
14:00).
– When all modifications have been made, turn the
en-
coder to select
“Confirm”
(Confirm) and press the
click
en-
coder to go back to
“Single days”
or
“Groups of days”
– press the
“ESC”
button to go back to the
“main screen”
.
Lun 1 Gen 2018
10:30
Zona
Acqua calda 48°C eco
Inverno automatico - set 20.0°C fino alle 7.30
Menu
Modo
Fig. 80