OPERATING INSTRUCTIONS FOR THE USER
THE GAS SAFETY (INSTALLATION AND
USE) REGULATIONS 1996.
It is the law that all gas appliances
are installed by a registered person, in
accordance with the above regulations.
Failure to install appliances correctly
could lead to prosecution. It is in your
own interest, and that of safety, to ensure
that the law is complied with.
It is essential that the appliance is cor-
rectly earthed. An electricity supply of
240 V - 50 Hz fused at 3 A is required.
Read these instructions carefully before
attempting to operate the appliance.
1.1
INTRODUCTION
The Sime “MURELLE ELITE HE 30-35”
family are fully automatic, wall mounted,
room sealed, fan assisted range of com-
bination boilers.
When operating in winter mode, the
appliance provides central heating as
required and produces instantaneous hot
water upon demand. When operating in
summer mode, the central heating is
not operational however the appliance
continues to supply hot water whenever
it is required.
The Sime “MURELLE ELITE HE 35 T”
family is a fully automatic, wall mounted,
room sealed, fan assisted system boilers.
The boiler is fitted with a divertor valve
which enables the boiler to be directly
connected to a hot water cylinder.
1.2
APPLIANCE OPERATION
“MURELLE ELITE HE” - a demand of hot
water will be sensed by the appliance
detecting water flow (providing that the
flow rate is above 2 l/m - 0.5 gal/min).
The fan will start and the burner will
light at full output. If the draw off rate is
near the maximum design flow rate the
appliance will run continuously at full
output until a tap is either turned off or
the flow rate is reduced in which case
the heat output will reduce accordingly
to maintain a steady temperature.
Hot water is made available almost
immediately at the appliance outlet, but
the final temperature and time taken
for the hot water to reach a tap depends
upon the potentiometer setting, the rate
at which water is drawn off, and the
length of the pipe between the boiler and
the tap.
When the tap is turned off, the appliance
will revert to C.H. mode (if set on winter
position) otherwise the burner will be
extinguished pending the next demand
for hot water.
“MURELLE ELITE HE 30-35”
&
“MURELLE ELITE HE 35 T” - a demand
for heating will be sensed by the boiler,
The pump will start, and provide suffi-
cient circulation is detected, the fan will
start and the burner will light. The heat
output will be controlled by the heating
sensor and the user interface control.
1.3
OPERATING
INSTRUCTIONS
1.3.1 Boiler igni
tion (fig. 24)
The first ignition of the boiler must be
carried out by qualified technical per-
sonnel. Successively, if it is necessary to
start up the boiler again, adhere strictly
to the following instructions: open the
gas tap to allow the flow of the fuel.
Move the main switch of the system to
“ON”. When fuel is fed to the boiler, a se-
quence of checks will be carried out and
the display shows the normal condition
of the functioning, always indicating the
pressure of the system. If the blue lumi-
nous bar is on, this indicates the presen-
ce of voltage.
N.B.: The first press of any key (2) act
only to illuminate the display, succes-
sive presses will be recognised to alter
the mode or value.
Winter
Press the key
5
3
1
2
4
of the controls (pos. 2)
to activate the winter mode functioning
(heating and D.H.W.). The display will be
as shown in the figure.
Summer
Press the key
5
3
1
2
4
of the controls (pos. 2)
to activate the summer mode functioning
(only the production D.H.W.).
The display will be as shown in the figure.
Fig. 24
Apre
2
2
2
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Apre
2
2
2
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Apre
2
2
2
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Содержание MURELLE EV HE 30
Страница 3: ......
Страница 12: ...12 ANALOGIC RF TIME PROGRAMMER Code 8092231...
Страница 13: ...13 DIGITAL RF TIME PROGRAMMER Code 8092232...
Страница 14: ...14 NOTES...
Страница 15: ......