40
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
1.5
MAIN COMPONENTS
Fig. 3
Codice/Code 8111227
Modello/Model MURELLE EQUIPE 100 BOX ErP
Matricola/Serial n. 9999999999
PAR 1 = 6 (G20) / 14 (G31)
PAR 2 = 9
KEY
1 System return manifold
2 Gas tap
3 System supply manifold
4 Gas valve
5 Fan
6 Safety thermostat 100°C
7 Heating supply probe (SM)
8 Ignition electrode
9 Control panel
10 Detection electrode
11 Pressure transducer
12 Single module drain
13 Safety valve 3.5 bar
14 Pump high efficiency
15 System supply tap
16 3-way drain tap
17 Gas manifold
CAUTION: To access the control panel (9) remove
the two screws which secure it to the support
bracket and turn the panel downwards.
MODEL
SERIAL NUMBER
YEAR OF CONSTRUCTION
WATER CONTENT IN BOILER
HEAT INPUT MAX
HEAT OUTPUT MAX (80-60°C)
HEAT OUTPUT MAX (50-30°C)
MAX OPERATING PRESSURE
CONTENTS D.H.W.
HEAT INPUT MAX D.H.W.
MAX OPERATING PRESSURE D.H.W.
D.H.W. FLOW RATE
POWER SUPPLY
MAX POWER ABSORBED
COUNTRIES OF DESTINATION
CATEGORY
TYPE
CODE
DIRECTIVE OF REFERENCE
PIN NUMBER
HEAT INPUT MIN
HEAT OUTPUT MIN (80-60°C)
HEAT OUTPUT MIN (50-30°C)
MAX OPERATING PRESSURE
HEAT INPUT MIN D.H.W.
MAX OPERATING PRESSURE D.H.W.
ELECTRICAL PROTECTION GRADE
NOx CLASS
CODE GAS COUNCIL NUMBER (UK)
CERTIFICATION WRAS (UK)
TYPE OF GAS
GAS SUPPLY PRESSURE
CLASSIFICATIONS
Fig. 3/a
1.6
TECHNICAL DATA PLATE (fig. 3/a)