FOR THE INSTALLATION TECHNICIAN
CONTENTS
1
DEVICE DESCRIPTION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 36
2
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 41
3
FEATURES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 50
4
USE AND MAINTENANCE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 57
IMPORTANT
When turning the boiler on for the first time it is best to run the following checks:
– Make sure there are no flammable liquids or materials in the boiler’s near vicinity.
– Make sure that electrical connections are correct and that the grounding wire is connected to a good
grounding system.
– Open the gas tap and check the seal on the fixtures including the burner.
– Make sure that the boiler is set to operate with the type of gas supplied.
– Make sure that the exhaust flue is free and/or correctly assembled.
– Make sure that any shutters are open.
– Make sure that the system was filled with water and that all air was drained.
– Make sure the distributor is not obstructed.
– Discharge any air in the gas pipes by using the pressure escape on the gas valve.
FONDERIE SIME S.p.A.
located in Via Garbo 27 - Legnago (VR) - Italy declares that its hot water boilers, CE appro-
ved according to Gas Directive 90/396/CEE and equipped with safety thermostat calibrated to maximum 110°C,
are
exempt
from PED Directive 97/23/CEE application field because they meet the requisites foreseen in arti-
cle 1 comma 3.6 therein.
MURELLE EQUIPE 1
00-1
50 BO
X ErP - EN
GLISH
CONFORMITY
Our Company declares that MURELLE EQUIPE 100-150 ErP boilers comply with the essential requirements of the
following directives:
- Boiler Efficiency Directive 92/42/EEC
- Gas Appliances Directive 2009/142/EC
- Electromagnetic Compatibility Directive 2004/108/EC
- Low Voltage Directive 2006/95/EC
- Ecodesign Directive 2009/125/EC
- Regulation (EU) N. 813/2013 - 811/2013