background image

8

When the selector is in the “AUTO” position, boiler func-
tioning  is  automatically  controlled  on  the  basis  of  the
temperature  levels  and  time  periods  set.  The  second
selector must be in the “RUN” position to start.
The programming procedure is described below:

Setting the time

Set the selector to the “CLOCK“ position. Press “h” to
change the hour on the display, or “m” to change the
minutes. To set the day, press the “1…7” button until
the  arrow  is  pointing  to  the  correct  day  (1  =
Monday… 7 = Sunday).

Setting the program

The  time  clock  has  8  on  times  and  8  off  times.  To
make it easier to use, the time clock is supplied with
3 on times and 3 off times already set for each day
of the week, as shown below:

To select programmes other than those already set,
move the selector to position “P”; “0:001” will appear
on the display, in which the first three digits indicate
the hour and minutes, while the fourth digit identifies
the program number. Odd-numbered programs iden-
tify  requests  for  operation  (day  temperature),  in
which  case  the  light  bulb  symbol  will  appear  on  the
display,  while  even-numbered  programs  identify
drops  in  temperature  (night).  Use  the  “1…7”  key  to
select the day of the week (from 1 to 7) or days (1 ÷
5, 6 - 7; 1 ÷ 6 or every day if the program is to be
repeated  every  day  of  the  week).  Set  the  hour  and
minutes with the “h” and “m” buttons. 
Press “P” to store the operation in memory and go
on to the next program. Repeat the same procedure
to set the remaining programs.

When  finished  programming,  set  the  selector  to
“RUN” position. 

Deleting one or more programs

The  on  and  off  time  must  be  deleted  for  each  pro-
gram to be deleted. 
Set  selector  (2)  to  position  “P”.  Select  the  desired
program  with  button  (3),  then  press  button  (4)  to
delete the day setting (the triangular symbols for the
days should go away). If part of the program is dele-
ted,  when  you  set  selector  (2)  back  to  the  “RUN”
position  an  error  will  appear  in  the  clock  display,
referring to the program which is incorrect. 
To  delete  all  programs,  put  the  selector  in  position
“P” and press buttons (3) and (5) at the same time. 

Setting the SKIP function

The SKIP function deactivates programs for the next
day  and  resumes  regular  programming  24  hours
later. 
This  function  is  useful  if  you  will  be  out  all  day  and
don’t need heating. 
To start this function, press button (7), which is acti-
ve only when selector (2) is in “RUN” position. 
Once  you  have  selected  the  SKIP  function,  it  will  go
into effect at 0:00 of the next day for 24 hours. 
You cannot turn it off once it has started, so regular
programming  will  not  resume  until  24  hours  have
passed.  

DIGITAL TIME CLOCK -  Code 8092214

Program

Time

1

06,00

2

09,00

3

12,00

4

14,00

5

18,00

6

22,00

NOTE: No program is set from 7 through 17.

or

1  Manual/automatic operation selector
2  Program/schedule setting selector
3  Program button
4  Day of the week button
5  Hour button
6  Minute button
7  SKIP button
8  Reset button

Содержание Ecomfort Plus

Страница 1: ...ECOMFORT PLUS User instructions GB PLEASE LEAVE THIS INSTRUCTION WITH THE USER...

Страница 2: ......

Страница 3: ...CLOCK Code 8092214 8 ANALOGIC RF TIME PROGRAMMER Code 8092221 9 DIGITAL RF TIME PROGRAMMER Code 8092223 10 These appliances comply with the S E D B U K scheme band A CONTENTS VERY IMPORTANT PLEASE MA...

Страница 4: ...he appliance detecting water flow providing that the flow rate is above 2 l m 0 5 gal min The fan will start and the burner will light at full output If the draw off rate is near the maximum design fl...

Страница 5: ...s checked and serviced as necessary at regular intervals The frequency of servicing will depend upon the particular installation conditions and usage but in general once a year should be adequate It i...

Страница 6: ...red black the wire which is coloured brown must be connected to the ter minal marked with the letter L or coloured red 1 6 4 Ventilation If the appliance is installed in a cabinet the latter MUST NOT...

Страница 7: ...tappets that remain at the centre of the dial will be the OFF periods N B The smallest switching time ON or OFF is 15 minutes To select Timed mode move the selector switch in the middle of the clock f...

Страница 8: ...e the operation in memory and go on to the next program Repeat the same procedure to set the remaining programs When finished programming set the selector to RUN position Deleting one or more programs...

Страница 9: ...9 ANALOGIC RF TIME PROGRAMMER Code 8092221 The boiler will operate in emergency mode heating on for 4 min off for 9min if the batteries are removed or discharged...

Страница 10: ...10 DIGITAL RF TIME PROGRAMMER Code 8092223 The boiler will operate in emergency mode heating on for 4 min off for 9min if the batteries are removed or discharged...

Страница 11: ...and illustrations provided in this manual have been carefully prepared but we reserve the right to make changes and improvements in our products that may affect the accuracy of the information contain...

Страница 12: ...Documentation Dpt Sime Ltd 1a Blue Ridge Park Thunderhead Ridge Glasshoughton Castleford WF10 4UA Customer Service 0870 9911114 Sales 0870 9911116 Technical Support 0870 9911117 Main Fax 0870 9911115...

Отзывы: