102
–
Setting the time
To set the current day of the week
(1 = Monday/7 = Sunday)
To set the current hour
To set the current minute
Once the hour is completed, the setting of the hour changes.
12
13
14
With
and
keys the current hour is regulated. Pressing these keys together, the
regulation is speeded up in an increasing sense.
–
Programme for hot-water service
With the Logic Remote Control it is possible to manage the temperature of boiler unit on two
levels (a comfort level and one at reduced temperature) in accordance with the programme
chosen with parameter 62 (load hot-water service). To have access to the parameter press
the
and
keys for at least 5 seconds and then go along the entered lines with the
key until parameter 62 is reached. At this point four different programmes may be selected
with
o
keys, with the following characteristics:
0
= 24 hours/ day - Hot water always available at the temperature set in parameter 3.
1
= standard - Hot water according to the daily heating programme. In the comfort periods
of the heating the temperature of the boiler unit is regulated at the value set via para-
meter 61.
2
= sservice suspended.
3
= second daily programme (8) - Everyday of the week the temperature of the hot-water ser-
vice is set according to programme B. In this case the programming is one for all the days
of the week and three periods of time are available. In the periods of time set, the tem-
perature of the boiler unit is controlled via the temperature setting of parameter 61.
Start phase 1: preparation of the boiler unit to the comfort temperature
End phase 1: Temperature of boiler unit maintained at the reduced value
Start phase 2: Preparation of boiler unit to the comfort temperature
End phase 2: Temperature of boiler unit maintained at the reduced value
Start phase 3: preparation of boiler unit to the comfort temperature
End phase 3: Temperature of boiler unit maintained at the reduced value
5
6
7
8
9
10
–
Vacation function
To enter the number of days of absence.
In the display the vacation symbol will be shown (
), on the left the day of activa-
tion (1 = Monday/7 = Sunday) and on the right the number of vacation days.
18
During the vacation the regulator will be on the availability mode.
When the set days have elapsed, the regulator will go on to the automatic function.
NOTE:
The vacation period may be cancelled by pressing a key of the operating mode.
–
Current values
Display and setting of the gradient of the heating characteristics curve.
When the room temperature set is not reached choose the gradient
indicated in point 2.8.3
Display of the current boiler temperature.
Display of the current power of the burner and of the current operating mode
(
= = heating/
= hot-water service)
15
16
17
Содержание DEWY 30/80
Страница 1: ...Dewy 30 80 IT ES GB PT ...
Страница 2: ......
Страница 4: ......
Страница 108: ......
Страница 111: ......