NOTE:
When, in addition to the message "ALL ..." the symbol
h
also appears on the display, after having repaired the
fault, button
Y
must be pressed for approx. 3 seconds, and
then released. The boiler starts up again normally.
6.6
Fault / malfunction codes
Type
No.
Description
ALL
01
Air pressure switch fault
ALL
02
Low water pressure in system
ALL
03
High water pressure in system
ALL
05
Boiler delivery probe fault
ALL
06
No flame detection
ALL
07
Safety thermostat open or siphon pressure switch
fault
ALL
08
Fault in flame detection circuit
ALL
09
No water circulating in primary system
ALL
10
Hot water tank sensor/anti-freeze faulty
ALL
13
Smoke probe triggered
ALL
14
Smoke probe fault
ALL
15
Fan fault
ALL
19
External sensor fault
ALL
20
Mix 1 zone safety thermostat triggered
ALL
21
Mix 1 Zone valve delivery probe fault
ALL
22
Mix 2 zone safety thermostat triggered
ALL
23
Mix 2 Zone valve delivery probe fault
ALL
24
S1 solar probe fault
ALL
25
S2 solar probe fault
ALL
26
S3 solar probe fault
ALL
27
Solar application coherence fault – hydraulic
configuration
ALL
28
S3 input coherence fault
ALL
29
Number of expansion boards connected fault
ALL
30
System return probe fault
ALL
31
Cascade manifold probe fault
ALL
32
Three zone system configuration fault
ALL
33
Communication fault with RS485 board
ALL
34
Communication fault with RS485 board – CASCADE
ALL
35
Communication fault with RS485 boards
ALL
70
Cascade generic fault
ALL
71
Generic fault with cascade module
6.7
Checks and adjustments
After checking that the boiler is operating correctly, you must
take combustion readings as well as maximum and minimum
power readings, and check the combustion efficiency by
activating the
chimney sweeper function
.
6.7.1
Chimney sweeper function
The chimney sweeper function is used by the qualified
maintenance technician to check the gas pressure, detect the
combustion parameters and measure the combustion efficiency
when required by the legislation in force.
This function lasts 15 minutes and is activated by proceeding
as follows:
– with the boiler inactive, loosen the screw on the mains tapping
point (1) on the gas valve and connect a pressure gauge
GAS VALVE
ALU HE 80
ALU HE 116
ALU HE 160-200-240-280
1
1
1
Fig. 32
– activate a heat request
– press button
s
or
n
to activate the boiler.
Leave the appliance to stabilise, then:
– press and hold the
M
button for a few seconds, until you see
the
z
figure flashing
– press the
Z
button to operate the boiler on maximum power
(Qmax) as indicated on the display with
v
– check that the gas supply pressure is: G20=20 mbar -
G31=37mbar