Load loss accessory Ø 80 mm
Description
Code
Load loss (mm H
2
O)
Vera HE 25
Vera HE 30
Inlet
Outlet
Inlet
Outlet
90° curve MF
8077450
0,20
0,25
0,25
0,30
45° curve MF
8077451
0,15
0,15
0,20
0,20
Horizontal exten-
sion W. 1000 mm
8077351
0,15
0,15
0,20
0,20
Vertical extension
W. 1000 mm
8077351
0,15
0,15
0,20
0,20
Wall terminal
8089501
0,10
0,25
0,10
0,35
Roof outlet termi-
nal (*)
8091204
0,80
0,10
1,10
0,15
(*) The losses of the roof outlet terminal at inlet include the
manifold code 8091400.
NOTE:
for the boiler to operate correctly it is necessary that a
minimum distance of 0.50 m of the duct is respected with a 90°
inlet curve.
Example: calculation of the load loss of a
Vera HE 25
boiler.
Accessories Ø 80
mm
Code
Quan-
tity
Load loss (mm H
2
O)
Inlet
Outlet
Total
Extension W. 1000
mm (horizontal)
8077351
7
7 x 0,15
-
1,05
Extension W. 1000
mm (horizontal)
8077351
7
-
7 x 0,15
1,05
90° curve
8077450
2
2 x 0,20
-
0,40
90° curve
8077450
2
-
2 x 0,25
0,50
Wall terminal
8089501
2
0,10
0,25
0,35
TOTAL
3,35
(installation permitted since the total of the load loss of the ac-
cessories used is less than 15 mmH
2
O).
120
Ø 80
185
185
Ø 80
250
400
125
125
Fig. 25
6.13 Electrical connections
The power cable must be connected to a 230V (±10%) ~ 50 Hz
network, observing L-N polarity and the earth connection. The
network must have an omnipolar switch with category III over-
voltage, in compliance with the installation rules.
If this cable needs to be replaced, an original spare must be re-
quested from
Sime
.
Therefore only the connections of the original components as
shown in the table are needed. These are to be ordered sepa-
rately from the boiler.
DESCRIPTION
CODE
External sensor kit (ß=3435, NTC 10KOhm at 25°C)
8094101
Power cable (dedicated)
6323875
Remote control HOME (open therm)
8092280
Remote control HOME PLUS (open therm)
8092281
Relay board kit
8092264
m
CAUTION
The maintenance interventions described must ONLY
be carried out the professionally qualified personnel.
a
WARNING
Before carrying out any interventions described:
– set the main system switch to "OFF"
– close the gas valve
– make sure that no hot parts inside the appliance are
touched.
OFF
Fig. 26
To facilitate introduction of the connection wires of the optional
components into the boiler:
– remove the screws (1), pull the front panel (2) forwards and
release it from the top by lifting it
1
2
Fig. 27
Содержание 8115020
Страница 10: ...10 IT ...
Страница 20: ...20 IT ...
Страница 48: ...48 EN ...
Страница 58: ...58 EN ...
Страница 81: ...81 ...
Страница 82: ...82 ...
Страница 83: ...83 ...
Страница 84: ...Fonderie Sime S p A Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 www sime it ...