8.3.2
Pump
LED colour
Pump status
Fault
Possible solution
Red/Green flash-
ing
Turbine operation
The hydraulic system in the pump
is powered but the pump is not
receiving any mains voltage
- Check network voltage
Dry operation
Air in the pump
- Check for leaks in the system
Overloading
The motor has difficulties turning.
The number of revs is lower than for
normal operation
- Check network voltage
- Check the system flow rate/pressure
- Check the characteristics of the system water; clean
the system of any debris
Flashing red
Overvoltage/undervoltage
Power supply voltage too low/high
- Check network voltage
Excessive temperature
Excessive temperature inside the
pump
- Check the water temperature in relation to ambient
temperature
- Check network voltage
- Check the ambient operating conditions
Short circuit
Motor current too high
- Check network voltage
Lit red
"Permanent safety shutdown"
Impeller blocked
- REPLACE THE PUMP
Fault in the electronic board and/or
the motor
- REPLACE THE PUMP
LED off
Stationary
No electrical power
- Check the electrical power connection
LED faulty
- Check if the pump can operate
Electronic board faulty
- REPLACE THE PUMP
Содержание 8103047
Страница 2: ...2 ...
Страница 6: ...6 IT ...
Страница 12: ...12 IT ...
Страница 24: ...24 IT ...
Страница 45: ...45 IT ...
Страница 46: ...46 EN ...
Страница 50: ...50 EN ...
Страница 56: ...56 EN ...
Страница 68: ...68 EN ...
Страница 89: ...89 EN ...
Страница 93: ...93 EN IT ...
Страница 94: ...94 EN IT ...
Страница 95: ...95 ...
Страница 96: ...Fonderie Sime S p A Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 www sime it ...