high-voltage potential is always at risk of discharging to a lower potential. If this discharge path is through a
semiconductor device, it may result in destructive damage.
SIM8905A must be handled according to the ESD Association standard: ANSI/ESD S20.20-1999, Protection of
Electrical and Electronic Parts, Assemblies, and Equipment.
Table 29: ESD performance parameters
(
Temperature: 25
℃
, Humidity: 45%
)
Pin
Contact discharge
Air discharge
VBAT
±
5KV
±
10 KV
GND
±
5KV
±
12KV
Antenna
±
5KV
±
10KV
PWRKEY
±
4KV
±
6KV
Module Operating Frequencies
Table 30: Module operating frequencies
Frequency
Receive
Transmit
Physical channel
LTE B2
1930-1990 MHz
1850-1910 MHz
TX: 18600-19199
RX: 600-1199
LTE B4
2110-2155 MHz
1710-1755 MHz
TX: 19950-20399
RX: 1950-2399
LTE B5
869-894 MHz
824-849MHz
TX: 20400-20649
RX: 2400-2649
LTE B12
729-746MHz
699-716MHz
TX: 23010-23179
RX: 5010-5179
Module Output power
Table 31: Conducted transmission power
Frequency
Power
Min.
LTE-FDD B2
23dBm +/-2.7dB
<-40dBm
LTE-FDD B4
23dBm +/-2.7dB
<-40dBm
LTE-FDD B5
23dBm +/-2.7dB
<-40dBm
LTE-FDD B12
23dBm +/-2.7dB
<-40dBm