55
VBAT
-
-
4.5
V
Peak Current
0
-
2.0
A
VBUS
-
-
30
V
I
I
*
-
-
8
mA
I
O
*
-
-
8
mA
*
These parameters are for digital interface pins, such as keypad, GPIO, I2C, UART, LCD and PCM.
.
6.2
Recommended Operating Conditions
Table
39
: Recommended operating conditions
Symbol
Parameter
Min
Typ
Max
Unit
VBAT
Power supply voltage
3.4
4.0
4.4
V
T
OPER
Operating temperature
-40
+25
+85
℃
T
STG
Storage temperature
-45
+90
℃
6.3
Digital Interface Characteristics
Table 40: Digital interface characteristics
Symbol
Parameter
Min
Typ
Max
Unit
I
IH
High-level input current
-10
-
10
uA
I
IL
Low-level input current
-10
-
10
uA
V
IH
High-level input voltage
2.4
-
-
V
V
IL
Low-level input voltage
-
-
0.4
V
V
OH
High-level output voltage
2.7
-
-
V
V
OL
Low-level output voltage
-
-
0.1
V
* These parameters are for digital interface pins, such as keypad, GPIO, I
2
C, UART, LCD, PWMs and DEBUG.
6.4
SIM Card Interface Characteristics
Table 41: SIM card interface characteristics
Symbol
Parameter
Min
Typ
Max
Unit
I
IH
High-level input current
-1
-
1
uA
I
IL
Low-level input current
-1
-
1
uA
1.4
-
-
V
V
IH
High-level input voltage
2.4
-
-
V
-
-
0.27
V
V
IL
Low-level input voltage
0.4
V
1.62
-
-
V
V
OH
High-level output voltage
2.7
-
-
V
Содержание SIM808