Smart Machine Smart Decision
SIM800_Hardware Design_V1.10
24
2018-08-13
4.2.2.
Power off SIM800
SIM800 will be powered off in the following situations:
Normal power off procedure: power off SIM800 by the PWRKEY pin.
Normal power off procedure: power off SIM800 by AT command “AT+CPOWD=1”.
Abnormal power off: over-voltage or under-voltage automatic power off.
4.2.2.1.
Power off SIM800 by the PWRKEY Pin
User can power off SIM800 by pulling down the PWRKEY pin for at least 1.5 second and then release. Please
refer to the power on circuit. The power off sequence is illustrated in following figure.
PWRKEY
VDD_EXT
STATUS
1.5s<t<33s
VIL<0.7V
Serial port
Active
Undefined
(input)
t>3s
Figure 13: Timing of Power off SIM800 by PWRKEY
Note: When module is powered off by pulling down PWRKEY, the pull down time exceeds 33 seconds will
course the module power up.
This procedure makes the module log off from the network and allows the software to enter into a secure state to
save data before completely shut down.
Before the completion of the power off procedure, the module will send URC:
NORMAL POWER DOWN
At this moment, AT commands can not be executed any more, and only the RTC is still active. Power off mode
can also be indicated by STATUS pin, which is low level at this time.
4.2.2.2.
Power off SIM800 by AT Command
SIM800 can be powered down by AT command “AT+CPOWD=1”. This procedure makes the module log off from
the network and allows the software to enter into a secure state to save data before completely shut down.
Before the completion of the power off procedure, the module will send URC:
NORMAL POWER DOWN
At this moment, AT commands can not be executed any more, and only the RTC is still active. Power off mode
can also be indicated by STATUS pin, which is at low level at this time.