47
Figure 33: Synchrony timing
Figure 34: EXT CODEC to MODULE timing
Figure 35: MODULE to EXT CODEC timing
Table 30: Timing parameters
Parameter
Description
Min
Typ
Max Unit
T(sync)
PCM_SYNC cycle time
–
125
–
μs
T(synch)
PCM_SYNC high time
400
500
–
ns
T(syncl)
PCM_SYNC low time
–
124.5 –
μs
T(clk)
PCM_CLK cycle time
–
488
–
ns
T(clkh)
PCM_CLK high time
–
244
–
ns
T(clkl)
PCM_CLK low time
–
244
–
ns
T(susync)
PCM_SYNC setup time high before falling edge of
PCM_CLK
60
–
–
ns
T(hsync)
PCM_SYNC hold time after falling edge of
PCM_CLK
60
–
–
ns
T(sudin)
PCM_DIN setup time before falling edge of
PCM_CLK
50
–
–
ns
T(hdin)
PCM_DIN hold time after falling edge of
PCM_CLK
10
–
–
ns