Figure 15: Power on Timing Sequence
Table 5: Power on timing
Parameter
Description
Time value
Unit
Min.
Typ.
Max.
Ton
The time to pull POWER_ON down to power on
64
180
-
ms
TpD+
The time to indicate connecting with the network
-
-
5.5
s
Tpw+
The time to indicate the module is powered on
completely
-
-
4.5
s
Tuart
The time to enable UART
-
-
5
s