P-SH-N-Ex 97.52.03.14.20
01/08
15
−
Make sure that the equipment is properly earthed, by means of the (main) voltage
connection.
−
Fit a line-side fuse in the connecting line.
−
A neon lamp (230 V) can be fitted as high-voltage indicator between the signal wire and
earth, see Figure 1,2 or 3. Also a relay can be fitted which triggers an alarm signal if the high
voltage fails.
−
Connect the connecting line.
Figure 1: connection of the Neoprene power cord.
Figure 2: connection of the shielded power cord.
Figure 3: connection of the SOOW power cord.
6. Putting into use
The anti-static bar is put into operation by switching on the (mains) voltage.
The fuse should have a breaking capacity of
1500 A.
The breaking capacity is the maximum short
circuit current that the fuselink can safely
interrupt.