background image

scorpION3 5200969 Rev 4

41

5.2 Parts & Accessories

Part Nos.

Description

4015454

18" ScorpION3 Ionizing Bar, Seven (7) Ultraclean Silicon emitters 

4015455

24" ScorpION3 Ionizing Bar, Seven (7) Ultraclean Silicon emitters 

4015456

36" ScorpION3 Ionizing Bar, Eleven (11) Ultraclean Silicon emitters 

4015457

44" ScorpION3 Ionizing Bar, Fifteen (15) Ultraclean Silicon emitters 

4015458

64" ScorpION3 Ionizing Bar, Nineteen (19) Ultraclean Silicon emitters 

4015459

74" ScorpION3 Ionizing Bar, Nineteen (19) Ultraclean Silicon emitters 

4015460

84" ScorpION3 Ionizing Bar, Nineteen (19) Ultraclean Silicon emitters 

4011546

18" ScorpION3 Ionizing Bar, Seven (7) Tungsten (W) emitters 

4011547

24" ScorpION3 Ionizing Bar, Seven (7) Tungsten (W) emitters 

4011548

36" ScorpION3 Ionizing Bar, Eleven (11) Tungsten (W) emitters 

4011549

44" ScorpION3 Ionizing Bar, Fifteen (15) Tungsten (W) emitters 

4011550

64" ScorpION3 Ionizing Bar, Nineteen (19) Tungsten (W) emitters 

4011551

74" ScorpION3 Ionizing Bar, Nineteen (19) Tungsten (W) emitters 

4011552

84" ScorpION3 Ionizing Bar, Nineteen (19) Tungsten (W) emitters 

4015461

18" ScorpION3 Ionizing Bar w/Air Assist, Seven (7) Ultraclean Silicon emitters 

4015462

24" ScorpION3 Ionizing Bar w/Air Assist, Seven (7) Ultraclean Silicon emitters 

4015463

36" ScorpION3 Ionizing Bar w/Air Assist, Eleven (11) Ultraclean Silicon emitters 

4015464

44" ScorpION3 Ionizing Bar w/Air Assist, Fifteen (15) Ultraclean Silicon emitters 

4015465

64" ScorpION3 Ionizing Bar w/Air Assist, Nineteen (19) Ultraclean Silicon emitters 

4015466

74" ScorpION3 Ionizing Bar w/Air Assist, Nineteen (19) Ultraclean Silicon emitters 

4015467

84" ScorpION3 Ionizing Bar w/Air Assist, Nineteen (19) Ultraclean Silicon emitters 

4011560

18" ScorpION3 Ionizing Bar w/Air Assist, Seven (7) Tungsten (W) emitters 

4011561

24" ScorpION3 Ionizing Bar w/Air Assist, Seven (7) Tungsten (W) emitters 

4011562

36" ScorpION3 Ionizing Bar w/Air Assist, Eleven (11) Tungsten (W) emitters 

4011563

44" ScorpION3 Ionizing Bar w/Air Assist, Fifteen (15) Tungsten (W) emitters 

4011564

64" ScorpION3 Ionizing Bar w/Air Assist, Nineteen (19) Tungsten (W) emitters 

4011565

74" ScorpION3 Ionizing Bar w/Air Assist, Nineteen (19) Tungsten (W) emitters 

4011566

84" ScorpION3 Ionizing Bar w/Air Assist, Nineteen (19) Tungsten (W) emitters 

5051195

Modular Interconnect Cable, 152 mm (6”)

5051168

Modular Interconnect Cable, 406 mm (16”)

5051196

Modular Interconnect Cable, 610 mm (24”)

Содержание scorpION3

Страница 1: ...I O N I Z A T I O N S O L U T I O N S Ionizing Bar System scorpION3TM User s Manual...

Страница 2: ...roducts and services Simco Ion improves its customers business results by providing a total solution to their electrostatic discharge and electromagnetic interference challenges Simco Ion Technology G...

Страница 3: ...electrical characteristics as outlined in this document Incorrect power connections to the bar can result in damage to the scorpION3 bar and or to user power supply User connections to the fault outp...

Страница 4: ...ue d crit dans le pr sent docu ment Mauvaise connexion de l alimentation de la barre peut entra ner des dommages au scorpion3 bar et ou l utilisateur d alimentation Connexions de l utilisateur la sort...

Страница 5: ...onsiderations 7 2 3 Bar Configuration 10 2 4 Multi Bar Installations 11 2 5 Air Assist optional 12 2 6 MMI Man Machine Interface 13 2 7 CI Computer Interface 21 3 Operation 25 3 1 Settings 26 4 Mainte...

Страница 6: ...scorpION3 5200969 Rev 4 1 1 Description 1 1 scorpION3 Ionizing Bar System 1 2 Features...

Страница 7: ...mco Ion s innovative and effective microcontroller intelligent ionization technology The system provides rapid neutralization of static charges over a localized work area or a mini environment It is t...

Страница 8: ...lance can be made to individual scorpION3 bars via the hand held MMI module Man Machine Interface which features two way communication with the bars via wireless infrared or hardwired RS 485 on a modu...

Страница 9: ...rminal Allows addressable control of up to 10 individual bars Remotely adjusts ionization parameters for calibration Acquires diagnostic information from the system Two way communication enables displ...

Страница 10: ...00969 Rev 4 5 2 Installation 2 1 Mounting Considerations 2 2 Wiring Considerations 2 3 Bar Configuration 2 4 Multi Bar Installations 2 5 Air Assist optional 2 6 MMI Man Machine Interface 2 7 CI Comput...

Страница 11: ...ted using hardware not provided with the unit it is important to keep any grounded hardware away from the emitter tips Introducing a ground near the emitter tips can affect ion balance and discharge t...

Страница 12: ...utlet of 100 to 240 VAC 50 or 60 HZ Connect the adapter to one of the scorpION3 bars with a modular cable The power will automatically be distributed to the other bars in the chain The scorpION3 bar h...

Страница 13: ...y closed N C by changing The scorpION3 is internally fused to protect the user s power supply during this type of setup Le scorpION3 est fusible interne afin de prot ger l utilisateur d alimentation p...

Страница 14: ...ith the MMI or through configuration software using the CI The fault output transistor may be used to provide switching in order to drive a variety of low current devices such as LEDs or buzzers relay...

Страница 15: ...to show the receipt of IR commands from the MMI Each scorpION3 bar can be assigned a unique address Addresses are numbers 0 9 and in multi bar systems each bar must have a unique address Address 0 des...

Страница 16: ...be exceeded Bar address numbers should not be duplicated on a given chain Having more than one bar 0 will cause communication conflict on the chain Address 0 designates the bar as the master and other...

Страница 17: ...tubing 1 4 OD polyethylene polyurethane nylon etc To make connection with the fitting insert the tubing until it stops To remove tubing from the fitting depress the collar on the fitting and pull the...

Страница 18: ...ing green indicators on the bar and MMI If the MMI indicator flashes red the MMI was unable to establish two way communication and realignment of the IR transceivers may be required The green indicato...

Страница 19: ...Pressing the Enter button establishes communication with the bar The green lights on the bar and the MMI will flicker indicating successful communication of the operating parameters The MMI will displ...

Страница 20: ...roll through bar system monitor or the preset numbers and the selection is activated by pressing the right arrow button Select Bar enters a menu where the bar address can be selected by scrolling thro...

Страница 21: ...in a system Output default 50 may be adjusted for the bar Using the up down arrows adjusts the bar output setting Output level sets the ionization output from the ionizer This value should be set to...

Страница 22: ...ower supplies according to the pulse time the cycle time of positive and negative ionization does not change however overlap will cause the power supply to extend its run time determined by the percen...

Страница 23: ...This is the option to saving the changes local to bar It allows selection of the desired preset number P1 through P14 and saving the parameters under this preset for later downloading into a bar Uplo...

Страница 24: ...gh voltage supplies The range for this value is from 0 to 1024 Typically this value should be between approximately 100 and 924 Fault Code Status Screen appears as follows N indicates a normal status...

Страница 25: ...Select Bar Preset or System Monitor review and adjustment of any of the 14 P1 through P14 preset operating parameters may be selected The menus under the Preset selection are the same as under the bar...

Страница 26: ...omputer or local computer network The green LED Power indicator illuminates to indicate power and flickers if an MMI is on the system chain transmitting commands The red LED Fault indicator illuminate...

Страница 27: ...he fault alarm Pin 4 is Common Pin 3 is Normally Closed Pin 5 is Normally Open The relay contacts are rated for a maximum of 1 A at 30 VDC resistive with a maximum switching voltage of 220 VDC The Com...

Страница 28: ...face provides continuous monitoring of the bar system set up and operating parameters the ability to adjust parameters and display of diagnostic information Detailed information on the Computer Interf...

Страница 29: ...scorpION3 5200969 Rev 4 24...

Страница 30: ...scorpION3 5200969 Rev 4 25 3 Operation 3 1 Settings...

Страница 31: ...ap can reduce space charge in pulsed mode Balance adjustment should be made after setting output current pulse time and overlap Adjustments must be saved using save settings local to bar Setup Recomme...

Страница 32: ...STM 3 1 should be used for this purpose Approx Distance Offset Volts Discharge Time sec Bar Mode Pulse Time sec Pulse Overlap Output Level 300 mm 12 15 6 SS 30 450 mm 18 10 10 SS 40 30 9 pulse 0 50 0...

Страница 33: ...pION3 bar with Air Assist provides reduced discharge times according to the following table Table 4 scorpION3 with Air Assist Typical Discharge Time Reduction The typical recommended operating pressur...

Страница 34: ...scorpION3 5200969 Rev 4 29 4 Maintenance 4 1 Cleaning Calibration 4 2 Cleaning the Emitters 4 3 System Calibration 4 4 System Diagnostics...

Страница 35: ...h the electric field around the emitter The emitter material has little or no relationship to the formation of these deposits Your process and system performance demands must be considered when determ...

Страница 36: ...ned from local cleanroom product suppliers 3 The TX726 CrushTube swab is shipped with a protective sleeve covering the white foam swab end Remove the protective sleeve to expose the swab end Discard t...

Страница 37: ...ON3 5200969 Rev 4 32 swab fails to remove the material a new swab should be used Clean all the emitter electrode points 4 The bar housing can be cleaned using a cleanroom wiper or soft cloth as approp...

Страница 38: ...3 5200969 Rev 4 33 5 Allow all alcohol to evaporate before applying power to the bar 6 It is recommended practice to develop a regular cleaning schedule that meets your requirements and operating cond...

Страница 39: ...be made only after the emitters have been cleaned and after every emitter cleaning or replacement Adjustments must be saved using save settings local to bar or they will be lost when power is removed...

Страница 40: ...th the scorpION3 bar When the diagnostic menus are entered the MMI downloads settings and operating data from the bar This information is displayed in a series of menus on the MMI A further descriptio...

Страница 41: ...scorpION3 5200969 Rev 4 36...

Страница 42: ...scorpION3 5200969 Rev 4 37 5 Specifications 5 1 Specifications 5 2 Parts Accessories...

Страница 43: ...tem slave bars will follow the pulse timing of the master bar Communications RS 485 Fault Interface 3 5 mm 1 8 phone jack opto isolated transistor that can be set to normally off or normally on this t...

Страница 44: ...t through 3 pin IEC320 receptacle Output Voltage 24 VDC 18W 0 75A Adapter powers a system of up to three bars any length with one communication module CI and one hardwired Man Machine Interface contro...

Страница 45: ...RJ 11 modular connectors or User Interface terminal block Bar Connection RJ 11 modular jack modular wire power communication Network Interface Ethernet RJ 45 modular connector LED Indicators Green PO...

Страница 46: ...nizing Bar w Air Assist Seven 7 Ultraclean Silicon emitters 4015462 24 ScorpION3 Ionizing Bar w Air Assist Seven 7 Ultraclean Silicon emitters 4015463 36 ScorpION3 Ionizing Bar w Air Assist Eleven 11...

Страница 47: ...100 240VAC Universal Input with North American NEMA5 15P Japan Line Cord 5051329 ScorpION2 3 AC Adapter 24VDC Out 100 240 VAC Universal Input with European CEE7 Line Cord 5051330 ScorpION2 3 AC Adapt...

Страница 48: ...ing repairing or replacing any unit returned to Simco Ion that has not been subjected to misuse neglect lack of routine maintenance repair alteration or accident In no event shall Simco Ion be liable...

Страница 49: ...scorpION3 5200969 Rev 4 44...

Страница 50: ...test wired searching select bar preset or sysmon bar scroll list LEDs on selected bar flash bar change address select settings or diagnostics WIRED SETTINGS NAVIGATION power output pulse steady state...

Страница 51: ...set upload to bar 1 not present if in steady state 2 not present if slave Hot Keys are NOT enabled UPLOAD PRESET NAVIGATION select bar enter execute transmit preset settings to bar SYSTEM MONITOR MMI...

Страница 52: ...atus accumulators bar information serial number reset bar command point MMI enter execute ADDRESS TEST searching for address conflicts accept or change address conflicts change desired address HOT KEY...

Страница 53: ...y Replace bar 2 Negative Ion Output Too Low Emitters need cleaning Emitter housing or emitter electrode not seated HV open circuit Neg HV supply is faulty Clean emitters Check emitter housing emitter...

Страница 54: ...Adjust Balance setting Increase Ion Output setting Adjust humidity or airflow Relocate bar or ground plane Replace bar 7 Program Voltage Error I O board fault Replace I O board Replace bar 8 Pos Contr...

Страница 55: ...scorpION3 5200969 Rev 4 50 Notes...

Страница 56: ...wy Ste 150 Alameda CA USA 94502 Tel 510 217 0600 Fax 510 217 0484 Toll free 800 367 2452 Sales services 510 217 0460 Tech support 510 217 0470 ioninfo simco ion com salesservices simco ion com techsup...

Отзывы: