![Simco-Ion IQ Power HL Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/simco-ion/iq-power-hl/iq-power-hl_installation-and-operating-instructions-manual_1274778012.webp)
10
IQ Power HL Power Supply
5201258 Rev. C
Reposition jumper to enable remote control either “normally on” or “normally
off”, as desired (see Figure 4). Then replace cover and secure with six screws.
When operating a power supply using the remote control circuit, power may
be applied through the “Alarm Output” connector or the “Power In” connector
on end panel. If the “Power In” connector on end panel is used, the “Power”
switch must be set to ON (1) position.
Remote control is established by applying 24 VDC to the “Alarm Output”
connector pins as specified in Figure 4. User-applied 24 VDC drives a low
current optoisolator on the IQ Power HL Power Supply main circuit board,
turning power supply on or off, depending on configuration of jumper J3.
NOTE
– DO NOT USE standard Ethernet cables with IQ Power systems.
Avoid permanent equipment damage by using only Simco-Ion modular
cables. (Refer to Section 8, Parts & Accessories).
Figure 5: IQ Power Crossover Modular Cable (black)
E.
Connect AC Adapter
(AC adapter not required if power supply is connected to
a Control Station.) Make sure “POWER” switch on power supply is in “OFF”
(0) position. Route low voltage wire clear of moving machine parts and protect
it from abrasion. Secure using nylon wire ties (not supplied). Do not over
tighten. Insert barrel connector into “POWER IN” connector on power supply.
Hand tighten barrel connector nut to secure.