E
N
SD
I0
1
In
cl
in
o
m
e
te
r
9
8.
Configuring SDI01 inclinometer module
Although the module is designed so that is works more or less out of the box
(requiring only calibration), there is a variety of settings available for user to
configure.
8.1 Name
The display name of your inclinometer. You can select either PITCH or ROLL.
8.2 Nonlinear
This parameter is for display purposes. By configuring NONLINEAR setting to
OFF, the inclination line will follow the angle values read by the sensor more
closely. This means that at the lower angles (1°–10°) the drawn offset may not be
as apparent.
The default value is ON.
8.3 Display
The parameter determines if the inclinometer is to be displayed on the
inclinometers screen.
The default value is ON.
8.4 Reverse
Reverses the display, which means that at the 5° angle the angle will be
presented as –5°. This gives the user more options when first mounting the
module to its location.