E
N
C
A
R
A
V
A
N
S
P
D
U
-5
2
8
4.7
Relays, Inputs
A - Relays K1-K6
The configuration for the functionality of the K1–K6 buttons can be changed
in the program. The default settings however, are the following:
·
K1 - Fridge
·
K2 - Heating
·
K3 - AC
·
K4 - Aux
·
K5 - Water pump
·
K6 - Lighting
B - Connections
C - Connection inputs and outputs
5.
Connecting
The Caravan Panel must be connected to the third port on the SPDU-52
(SICOM PANEL) or it will not work.
If you have an Inclinometer module you can connect it directly to the
second port of the Caravan Panel or you can connect the module to SiCOM
port 1 or SiCOM port 2.
Resistance inputs can be used to connect the temperature sensor,
resistance tank sensor, the 4 stage level tank, any resistance based
sensor, etc.
Auxiliary voltage input, can be used to connect any sensor that outputs
voltage.