Page 14 /14
10 Terminal connection diagram for 3-phase motor
Attention:
To prevent the risk of a short-circuit,
terminals
L
and
N
must not be interchanged !
11 Fuse
SI 1 and SI 2
6,3A respectively (slow-blowing) 1 spare is added part.
SI 3
1,0A (slow-blowing)
12 Technical data
Supply voltage:
230V AC / 50Hz
via a power supply cord with integral earthing-pin plug.
Motor connection:
230V AC / 4A
via motor connection cable with fitted socket connector.
Valve connection:
24 V DC / 0,5A
via valve cable with fitted solenoid valve connector (black)
Type of protection:
IP54
Subject to change
Gebläsestarter
XS3
N
2
L1
3
L-Schalt
1
PE
Relais-ON
1
FX-Steuerung
X2
PE
N1
X6
L1
X1
Ausgang
X5
Fan Starter
Output
FX control unit