Trouble shooting
Trouble
Possible Cause
Possible trouble shooting
Discharge flap does not close. Clean and adjust discharge flap.
Separator full
Set conveying time is too long.
Set shorter conveying time.
No conveying
although vacuum
pump in operation.
Conveying piping clogged.
Clean conveying piping;
Change setting of suction pipe,
if necessary.
Magnetic switch on flap is
defective or maladjusted.
Replace or readjust magnetic
switch on flap
.
Mains fuse released
Measure current consumption
and check fan for overload
.
Blower unit defective
Replace fan.
Check motor brushes.
Current supply interrupted
Check fuse of socket
Vacuum pump does
not operate although
discharge flap is
closed
Control unit defective.
Require spare control unit.
Conveying air filter clogged
Check function of filter cleaning.
Clean conveying air filter,
replace if necessary.
Conveying piping too long or
arranged adversely
Check piping arrangement;
void sharp bends and height
differences.
Use cleanout valve, if necessary
Conveying time set too short
or too long.
Set the conveying time so that
the separator is just filled
Unit works at
reduced
conveying capacity
Conveying filter is clogged
Clean and check conveying air
filter for damage
Repair work is to be carried out only with mains plug
and compressed air disconnected from supply !
Our service phone: + 49 (0)7042 / 903 17
t
Содержание FX 2004
Страница 10: ...Page 10 26 3 3 Connection FX controller to EKO blow unit...
Страница 19: ...Page 19 26 10 Dimension sheet 10 1 Dimension sheet FX 2004...
Страница 20: ...Page 20 26 10 2 Dimension sheet FX 2504...
Страница 21: ...Page 21 26 11 Spare parts 11 1Spare parts FX 2004 E 10 2004...
Страница 22: ......
Страница 23: ......
Страница 24: ...Page 23 26 11 2Spare parts FX 2504 E 10 2504...
Страница 25: ......
Страница 26: ......
Страница 29: ...Page 3 14 Attention If the controller ist opened without our permission the warranty will expire...
Страница 41: ......